Keyword reference
XFAX - User’s Guide 4.3a
52
Standard value: “lp”
15.1.52 LP_PRINT_OPTION
LP_PRINT_OPTION=string
Indicates which parameters are used together with the printout program, nor-
mally 1p, to indicate a special printer, e.g. “1p -d laser”.
Standard value: “-d”
15.1.53 MAIL_ON_ERROR
MAIL_ON_ERROR
Indicates that the mail should be sent to the user who has placed a fax in the
queue if it has not been possible to send it.
15.1.54 MAIL_ON_SUCCESS
MAIL_ON_SUCCESS
Indicates that mail should be sent to the user who has placed a fax in the queue if
the fax has been sent with the status OK.
15.1.55 MAX_BPS
MAX_BPS=speed
Indicates the maximum speed of the fax modem when sending a fax in the unit
bits per second (bps). Permitted values: 14400, 9600, 7200, 4800 and 2400.
Standard value: 14400
15.1.56 MAX_TRIES
MAX_TRIES=number of retries
Gives the maximum number of times a fax should be tried to be sent before the
system gives up and places it in the queue for faxes not sent.
15.1.57 NICE_CONV
NICE_CONV=priority
Indicates that a lower priority than normal should be used when converting a fax.
The value can be between 0 and 20. 20 gives the lowest priority.
15.1.58 NICE_SEND
NICE_SEND=priority
Indicates that higher priority than normal should be used for sending a fax.
The value can be between 0 and 20. 20 gives the highest priority.