HYDRAULIC
Anchor Applicator Model BAAM
Section H-6
MAR/2005 (49454100)
MAIN SYSTEM PRESSURE & RELIEF SETTINGS
Install the pressure gauge on the pressure tap for the main system pump
as shown in the picture at the left.
Turn relief valve adjustment screw to full clockwise (CW) position
(maximum pressure).
Turn pump compensator screw counterclockwise (CCW) (about 2-3
turns), but do not remove screw. Leave enough thread engagement to
prevent leakage. Start engine and turn on the Pump.
Turn pump compensator clockwise (CW)until 3000 psi has been
reached. Read this pressure at the main system gage on the propulsion
manifold.
Adjust relief counterclockwise (CCW) until pressure at gauge just begins
to drop. This is considered cracking pressure. Turn back 1/8 of a turn
and tighten locknut.
DO NOT ADJUST THE RELIEF VALVE FOR FULL FLOW PRESSURE!
Refer to next page to set Crossover Relief Valves.