![Nordcap CLIO 2 L1 1562 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/nordcap/clio-2-l1-1562/clio-2-l1-1562_use-and-maintenance-manual_1701396024.webp)
5
Serial number plate
Environmental climatic classes according to ISO 23953
-
2
* With reference to environmental climate classes, this is to specify that when climate class 3 is indi-
cated, it means that climate class 3 or lower can be valid.
Climate class
Dry bulb temp.
Relative humidity
Dew point
1
16°C
80%
12°C
2
22°C
65%
15°C
3*
25°C
60%
17°C
4
30°C
55%
20°C
5
40°C
40%
24°C
6
27°C
70%
21°C
Serial nr
2020
Model
Code
Rated
1
2
3
Heating elements
4
Defrosting
5
6
Circuit
Refrigerant
GWP
Loaded Q.ty
Q.ty CO
2
Compressor
1
7
8
7
9
10
Climate Class
11
Temeperature Class
12
Foaming Fluid
H
2
O
WARNING: System contains refrigerant under high pressu-
re. Do not tamper with the system. It must be serviced by
qualified persons only.
1.
Rated power
7.
Refrigerant fluid/Refrig. fluid mass (Plug
-
in)
2.
Standard absorbed current
8.
Global warming potential
3.
Voltage
9.
Quantity CO
2
(GWP x Loaded Q.ty) (Plug
-
in)
4.
Other heating elements (if any)
10.
Compressor model (if present)
5.
Maximum defrost power
11.
Climate class (see table)
6.
Maximum light bulb power (if present)
12.
Temperature Class (ISO 23953
-
2)