ERROR LIST
Alarm
Description
WARNING! NO COMMUNICATION
BETWEEN THE KEYBOARD AND THE BASE
NO ACTION POSSIBLE CONTACT TECHNICAL
SUPPORT
system error, contact technical support.
WARNING! SAFETY THERMOSTAT
TRIGGERED SWITCH OFF THE BLAST
CHILLER. IT IS NECESSARY TO RESTORE THE
SAFETY THERMOSTAT AND IF THE
MALFUNCTION PERSISTS, CONTACT
TECHNICAL SUPPORT
Thermostat triggered, contact technical
support to restore the thermostat.
WARNING! CELL PROBE MALFUNCTION,
COOLING IMPOSSIBLE WITHOUT A
RELIABLE TEMPERATURE REFERENCE
Cell probe faulty, contact technical
support.
WARNING! HIGH TEMPERATURE IN
COMPONENTS COMPARTMENT, SWITCH
OFF THE BLAST CHILLER. IF THE
MALFUNCTION PERSISTS AFTER ONE
HOUR, CONTACT TECHNICAL SUPPORT
Follow the instructions on the screen. If
the problem persists, contact technical
support.
WARNING! HIGH PRESSURE PRESSURE
SWITCH TRIGGERED, SWITCH OFF THE
MACHINE. IT IS NECESSARY TO RESTORE
THE SAFETY PRESSURE SWITCH, IF THE
MALFUNCTION PERSISTS CONTACT
TECHNICAL SUPPORT
(A) Check that there are no obstructions
in front of the condenser grid (B) Check
that the condensing coil is not obstructed
or dirty. C) Check that the distance
between the wall and the back of the
machine is at least 15cm (D) Check that
the temperature in the workplace is not
higher than 33°C. If the problem persists,
contact technical support.
WARNING! EVAPORATOR PROBE
MALFUNCTION, COOLING IMPOSSIBLE
WITHOUT A RELIABLE TEMPERATURE
REFERENCE
Evaporator probe faulty, contact
technical support.
WARNING! CORE PROBE MALFUNCTION.
DISCONNECT THE CORE PROBE. IT IS
POSSIBLE TO CONTINUE BAKING ONLY
WITH TIME CONTROL. REPLACE THE CORE
PROBE.
Core probe faulty. Replace the faulty
probe, If the problem persists contact
technical support.
WARNING! CONDENSER PROBE
MALFUNCTION
Condenser probe faulty, contact technical
support.
WARNING! HUMIDITY PROBE
MALFUNCTION
Humidity probe faulty, contact technical
support. (only in models with humidity
generator)