![Nordcap 402729447 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/nordcap/402729447/402729447_installation-and-operating-manual_1701388050.webp)
conditions and complying with the regulations in force, is installed between the power
cable and the electric line. For the correct sizing of the switch or plug, refer to the
absorbed current specified on the appliance data plate.
• After making the connection, with the appliance running check that the power supply
does not fluctuate by ±10% the rated voltage.
• If the power cable is damaged, it must be replaced by the Customer Care Service or in
any case by specialised personnel, in order prevent any risk.
• The manufacturer declines any liability for damage or injury resulting from breach of the
above rules or non-compliance with the electrical safety regulations in force in the
country where the machine is used.
Electrical connection for appliances with plug
• To connect to the power supply, insert the power cable plug in the corresponding mains
socket, first making sure:
• the socket has an efficient earth contact and the mains voltage and frequency match
that given on the dataplate. In case of any doubts regarding the efficiency of the earth
connection have the system checked by specialised personnel;
• the system power supply is arranged and able to take the actual current absorption and
that it is correctly executed according to the regulations in force in the country of use;
• The plug must be accessible after positioning the appliance in the place of installation;
• The plug must be in a position always visible to the operator performing the intervention
during maintenance operations;
Electrical connection for appliances with cable without plug
• The connection point has an efficient earth contact and the mains voltage and frequency
match that given on the data plate. In case of doubts regarding the efficiency of the earth
wire, have the system checked by specialised personnel;
• the appliance must be permanently connected to the power supply, respecting the
polarities:
– brown/black/gray: phase
– yellow/green: earth
– blue: neutral;
• An H05VV-F type power cable (code 60227 IEC 53) is used for the permanent
connection to the mains; in case of replacement, use a type with at least these
characteristics. When replacing the cable, the earth wire must be kept longer than the
live and neutral wires.
• The differential thermal-magnetic switch must be lockable in the open position in case of
maintenance.
• If using a plug, it must comply with the national installation rules. The plug must also be:
– accessible after the appliance has been positioned
– in the place of installation;
– in a position always visible to the operator performing the intervention during
maintenance operations;
Machine space limits
• Make sure to position the appliance at least 500 mm from the top and 50 mm from the
back and from any other machines present in the room (in fact, close proximity can
create problems of condensate forming on the walls of the appliance), also taking into
consideration the space needed for door opening.
17
Содержание 402729447
Страница 1: ...Bedienungsanweisung Umluft Gewerbek hlschrank KU 400 G W Art 402729447 2019 12...
Страница 7: ...EI Netzkabel 7...
Страница 10: ...K ENTSORGUNG DES GER TS 33 K 1 Entsorgung 33 K 2 Zerlegen des Ger ts 33 10...
Страница 34: ...Installation and Operating Manual Vertical Refrigerators KU 400 G W Art 402729447 2019 12...
Страница 35: ...Installation diagram High feet model 701 1766 150 EI 582 633 1276 399 92 518 92 118 116 57 587 57 2...
Страница 36: ...Installation diagram Low feet model 701 1654 582 123 457 53 EI 633 1276 457 123 25 651 25 53 54 592 54 3...
Страница 37: ...Installation diagram High wheels model 1775 701 582 118 399 116 633 40 EI 1276 399 91 5 518 91 5 118 116 4...
Страница 38: ...Installation diagram High feet glass door model 1766 150 EI 590 641 1280 701 399 92 518 92 118 124 57 587 57 5...
Страница 39: ...Installation diagram Low feet glass door model 701 1654 34 590 641 EI 1280 54 592 54 123 457 61 651 25 25 6...
Страница 40: ...EI Power cable 7...
Страница 43: ...K MACHINE DISPOSAL 31 K 1 Waste storage 31 K 2 Procedure regarding appliance dismantling macro operations 31 10...