6. Appendix
www.nord.com B1050-GB-0213
-31-
6.2 Lubricant quantities
Note!
After changing the lubricant, and in particular after the initial filling, the oil level may change
during the first few hours of operation, as the oil galleries and hollow spaces only fill gradually
during operation. The oil level is still within the permissible tolerance.
If at the express request of the customer, an oil inspection glass is installed at an additional
charge, we recommend that the customer corrects the oil level after an operating period of
approx. 2 hours, so that when the gear unit is at a standstill and has cooled down, the oil level
is visible in the inspection glass. Only then, is it possible to check the oil level by means of the
inspection glass.
Note!
The stated filling quantities are guide values. The exact quantities vary according to the exact
gear ratio. When filling, the precise quantity must be observed on the oil level indicator.
Note!
The values in brackets apply for circulation lubrication.
Helical gear units
[L]
M1
M2
M3
M4
M5
2)
M6
2)
max
3)
SK 7207
36
45
36
48
46
46
62
SK 7307
36
45
36
48
46
46
62
SK 8207
44
55
44
59
57
57
76
SK 8307
44
55
44
59
57
57
76
SK 9207
57
71
57
76
74
74
98
SK 9307
57
71
57
76
74
74
98
SK 10207
72
89
72
96
92
92
123
SK 10307
72
89
72
96
92
92
123
SK 11207
105
130 ( 50 )
105
140 ( 40 )
135 ( 45 )
135 ( 45 )
180
SK 11307
105
130 ( 50 )
105
140 ( 40 )
135 ( 45 )
135 ( 45 )
180
SK 12207
116
185 ( 83 )
116
203 ( 65 )
199 ( 69 )
199 ( 69 )
268
SK 12307
116
185 ( 83 )
116
203 ( 65 )
199 ( 69 )
199 ( 69 )
268