2 Migration
MI 0500 en-2922
25
Pos : 58 /Allgemein/Dokumenten Ü berschrif ten/M I/! Abs chnitt Funktionell e Sicherheit ( STO , SS1) @ 40\ mod_1580730649314_388. doc x @ 2588305 @ 2 @ 1
2.5 Functional safety (STO, SS1)
Pos : 59 /Migrati onsl eitf aden/N ORDAC PR O/ SK 5xxE - SK 5xxP/Migration/ On board F unkti onalit ät @ 83\mod_1637655595015_388. doc x @ 2847410 @ 3 @ 1
2.5.1 On board functionality
For the SK 510E, SK 511E, SK 530E, SK 535E, SK 540E and SK 545E performance levels, the
functional safety is integrated in the device for the 230 V and 400 V mains voltages. This integrated
function variant is only available for the SK 510P.
SK 5xxE
Functions
Connection
SK 51xP
Designation
Part No.
Product
Product
Designation
Part No.
SK 510E-xxx-323-A
Safe stop
STO, SS1
1-channel
on board
275 71x xxx
SK 510E-xxx-340-x
275 72x xxx
SK 511E-xxx-323-A
275 291 xxx
275 77x xxx
SK 511E-xxx-340-x
275 78x xxx
Table 11: Functional safety as integrated function (on board)
Information
The functional safety (STO, SS1) is described device-specifically in supplementary manuals.
For detailed information, please refer to the
5.1.1 "Manuals" supplementary manuals on the
functional safety.
Pos : 60 /Migrati onsl eitf aden/N ORDAC PR O/ SK 5xxE - SK 5xxP/Migration/ Kundensc hnitts tellen ( SK CU5-. ..) @ 83\ mod_1637656004243_388. doc x @ 2847448 @ 3 @ 1
2.5.2 Customer units (SK CU5-…)
For the SK 5xxP series, two functional extensions are available for the SK 530P and SK 550P
advanced performance levels. These optional SK CU5-... customer units are available in the functions:
SK CU5-STO functional
safety
SK CU5-MLT encoder
interface
STO, SS1
2-channel connection
STO, SS1
2-channel connection
TTL, SIN/COS, SSI,
Hiperface, Endat, BISS
Illustration 2: SK CU5-STO customer unit