Motors – Manual with installation instructions
36
B 1091 en-1221
Pos: 96 /Anleitungen/Motoren/B1091 Drehstrommotoren/3. ATEX/!2! Motoren für den Einsatz in der Zone 21 und Zone 22 nach EN 60079- 0 sowie IEC 60079_01 [Zon21+22] @ 67\mod_1613485501018_388.docx @ 2738783 @ 2 @ 1
3.3 Motors for use in Zone 21 and Zone 22 according to EN 60079 and
IEC 60079
Pos: 97 /Anleitungen/Motoren/B1091 Drehstrommotoren/Sicherheitshinweise/GEFAHR_ATEX - Explosionsgefahr Elektischer Schlag - Motoren [B1091] @ 11\mod_1460010132024_388.docx @ 316266 @ @ 1
DANGER!
Explosion hazard
All work must only be carried out with the machine at a standstill and the
power to the
system switched off
.
Higher temperatures than the maximum permitted surface temperature of the housing may be
present inside the motor. The motor must therefore never be opened in an explosive
atmosphere!
Failure to comply with this may result in the ignition of an explosive atmosphere.
Pos: 98 /Anleitungen/Motoren/B1091 Drehstrommotoren/Sicherheitshinweise/WARNUNG_ATEX_Explosionsgefahr-Thermisch - Motoren [B1091] @ 11\mod_1460010112266_388.docx @ 316231 @ @ 1
WARNING
Explosion hazard
Excessively heavy dust deposits must be avoided, as these impair the cooling of the device!
Impairment or obstruction of the flow of cooling air, for example due to partial or large area
coverage of the fan cover or the entry of foreign bodies fall into the fan must be avoided in
order to ensure adequate cooling.
Only cable glands and reducers which are approved for use in explosion hazard areas may be
used.
All cable glands which are not used must be closed with blind screw plugs which are approved
for potentially explosive areas.
Only the original seals may be used.
Failure to comply increases the risk of ignition of an explosive atmosphere.
Pos: 99 /Anleitungen/Motoren/B1091 Drehstrommotoren/3. ATEX/!2! Motoren für den Einsatz in der Zone 21 und Zone 22 nach EN 60079- 0 sowie IEC 60079_02 [Zon21+22] @ 67\mod_1613485637047_388.docx @ 2738821 @ @ 1
For these motors, the following information specifically or complimentarily apply.
Motors which comply with EN 60079 and IEC 60079 are suitable according to their labelling for use in
Zone 21 or Zone 22 - non-conductive dust.
Type suffix:
according to
EN 60079
Zone 21
2D
e.g.:
80 L/4 2D TF
Zone 22
3D
e.g.:
80 L/4 3D TF
according to
IEC 60079
Zone 21
EPL Db
e.g.:
80 L/4 IDB TF
Zone 22
EPL Dc
e.g.:
80 L/4 IDC TF
Labelling:
according to
IEC 60079 and
2014/34 EU
0102
II 2D Ex tb IIIC T125°C Db
For Category 2 (Zone 21)
1)
II 3D Ex tc IIIB T125°C Dc
For Category 3 (Zone 22 –
non-conducting dust)
1)
according to
IEC 60079
EX tb IIIC T125°C Db
For Category 2
1)
Ex tc IIIB T125°C Dc
For Category 3 (Zone 22 –
non-conducting dust)
1)
1)
The indicated surface temperature may deviate from 125°C and can be found on the name plate.
If the motor is connected to a gear unit, the gear unit’s Ex labelling must also be observed.
Содержание B1091
Страница 1: ...B 1091 en Motors Manual with installation instructions...
Страница 5: ...Publisher B 1091 en 1221 5...
Страница 55: ...6 Declarations of Conformity B 1091 en 1221 55 6 Declarations of Conformity...
Страница 56: ...Motors Manual with installation instructions 56 B 1091 en 1221...
Страница 57: ...6 Declarations of Conformity B 1091 en 1221 57...
Страница 58: ...Motors Manual with installation instructions 58 B 1091 en 1221 Ende der Liste f r Textmarke Inhalt...
Страница 60: ...6051302 1221...