![Norcool CAVE 45 BI DZ Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/norcool/cave-45-bi-dz/cave-45-bi-dz_operating-and-installation-instructions-manual_1701185016.webp)
16
7. Troubleshooting guide
PROBLEM
POSSIBLE CAUSE
Display flash and indicate “HH”, flash
speed one time per second
The temperature sensor of zone > 37˚C
Display flash and indicate “LL”, flash
speed one time per second
The temperature sensor of zone < 0˚C
Display flash and indicate “E0”, flash
speed one time per second
Connection failure, wire or component is not connected
Display flash and indicate “E1”, flash
speed one time per second
Temperature sensor is failure in corresponding zone
Display flash and indicate “E2”, flash
speed one time per second
Error defrost sensor in corresponding zone
Appliance does not operate
Not plugged in.
The circuit breaker has tripped or there is a blown
fuse.
Temperature inside the appliance is
too warm
Temperature control is set too warm. Turn the con-
trol to a cooler setting and allow several hours for the
temperature to stabilize.
Door is kept open too long or is opened too frequent-
ly. Warm air enters the appliance every time the door
is opvened. Open the door less often.
The door is not closed completely.
The door gasket does not seal properly.
The appliance has recently been disconnected for a
period of time. 4 hours are required for the appliance
to cool down completely.
Temperature inside the appliance is
too cold.
Temperature control is set too cold. Turn the control
to a warmer setting and allow several hours for the
temperature to stabilize.
Vibrations
Check to assure that the appliance is on a level surface.
The appliance is touching the wall. Re-level the
appliance and move it from the wall.
If continued vibration occurs, turn off the appliance
and unplug the power plug. Contact Customer Service
Dept. for further assistance.
Moisture forms on inside appliance
walls
Door is slightly open.
Door is kept open too long, or is opened too frequent-
ly. Open the door less often.
The door is not sealed properly
Moisture forms on outside of appliance
Door is slightly open, causing cold air from inside the
appliance to meet warm moist air from outside
Temperature inside the appliance is
too cold.
The appliance is not on a level surface.
The gasket is dirty.
For service, see our website at
www.norcool.com
By checking the above before ordering service, you will help the service engineer know
what parts they may need to bring and what measures to take.
Содержание CAVE 45 BI DZ
Страница 1: ...CAVE 45 BI DZ CAVE 60 BI DZ English OPERATING INSTALLATION INSTRUCTIONS...
Страница 2: ...2...
Страница 3: ...3 Please visit www norcool no for operating installation instructions in other languages...
Страница 18: ...18 Notes...
Страница 19: ...19 Notes...