Norcool CAVE 45 BI DZ Скачать руководство пользователя страница 16

16

7. Troubleshooting guide

PROBLEM

POSSIBLE CAUSE

Display flash and indicate “HH”, flash 
speed one time per second

The temperature sensor of zone > 37˚C

Display flash and indicate “LL”, flash 
speed one time per second

The temperature sensor of zone < 0˚C

Display flash and indicate “E0”, flash 
speed one time per second

Connection failure, wire or component is not connected

Display flash and indicate “E1”, flash 
speed one time per second

Temperature sensor is failure in corresponding zone

Display flash and indicate “E2”, flash 
speed one time per second

Error defrost sensor in corresponding zone

Appliance does not operate

Not plugged in.

The circuit breaker has tripped or there is a blown 

fuse.

Temperature inside the appliance is 

too warm

Temperature control is set too warm. Turn the con-

trol to a cooler setting and allow several hours for the 

temperature to stabilize.

Door is kept open too long or is opened too frequent-

ly. Warm air enters the appliance every time the door 

is opvened. Open the door less often.

The door is not closed completely.

The door gasket does not seal properly.

The appliance has recently been disconnected for a 

period of time. 4 hours are required for the appliance 

to cool down completely.

Temperature inside the appliance is 

too cold.

Temperature control is set too cold. Turn the control 

to a warmer setting and allow several hours for the 

temperature to stabilize.

Vibrations

Check to assure that the appliance is on a level surface.

The appliance is touching the wall. Re-level the 

appliance and move it from the wall.

If continued vibration occurs, turn off the appliance 

and unplug the power plug. Contact Customer Service 

Dept. for further assistance.

Moisture forms on inside appliance 

walls

Door is slightly open.

Door is kept open too long, or is opened too frequent-

ly. Open the door less often.

The door is not sealed properly

Moisture forms on outside of appliance

Door is slightly open, causing cold air from inside the 

appliance to meet warm moist air from outside

Temperature inside the appliance is 

too cold.

The appliance is not on a level surface.

The gasket is dirty.

For service, see our website at 

www.norcool.com

By checking the above before ordering service, you will help the service engineer know 

what parts they may need to bring and what measures to take.

Содержание CAVE 45 BI DZ

Страница 1: ...CAVE 45 BI DZ CAVE 60 BI DZ English OPERATING INSTALLATION INSTRUCTIONS...

Страница 2: ...2...

Страница 3: ...3 Please visit www norcool no for operating installation instructions in other languages...

Страница 4: ...nings 5 2 Components and parts 8 3 Installation 9 4 Appliance features and wine storage 11 5 Operating your appliance 13 6 Care and maintenance 15 7 Troubleshooting guide 16 8 Technical specifications...

Страница 5: ...ct from the mains Air the room in which the appliance is located for at least an hour Contact the manufacturer for further advice According to the EN378standard the room must be at least 1m3 per 8g of...

Страница 6: ...been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Read al...

Страница 7: ...roducts contain refrigerants which under the guidelines of federal law must be removed before disposal of product It is the consumer s responsibility to comply with federal and local regulations when...

Страница 8: ...1 Temperature control and display 2 Circulation fan 3 Interior light 4 Cabinet 5 Wooden shelves 1 2 4 3 5 Parts Upper zone controller display Lower zone controller display Warmer Warmer Light Light C...

Страница 9: ...installation Avoid locating the appliance in moist areas Plug the appliance into dedicated properly installed grounded wall outlet Do not under any circumstances cut or remove the third ground prong...

Страница 10: ...upplied This appliance requires a standard 220 240 Volt A C 50Hz electrical outlet This appliance is not designed to be used with an inverter The cord should be secured behind the appliance and not le...

Страница 11: ...y pressing the pad light on the control panel Long life and high efficiency LEDs are installed for durability and energy saving Engaged wine shelves All the shelves have tabs to engage the cabinet on...

Страница 12: ...r zone 11 Lower zone 6 pull out wooden shelves x1 11 Storage volume 50 liters Pull out shelf dimension 466 x 340 mm CAVE 45 Bi DZ Capacity CAVE 45 BI DZ 750 ml bottle 22 Upper zone 11 Lower zone 11 St...

Страница 13: ...ontrolled and displayed 3 The temperature in either zone can be controlled between 5 C to 20 C The zone temperature may have a tolerance of 3 C from setting depending on different loading and ambient...

Страница 14: ...elsius and Fahrenheit by pressing the K5 key K6 key upper interior light Interior light control switch of the upper zone To turn on or turn off the interior light by pressing the K6 key once for each...

Страница 15: ...and exterior with a soft cloth Dust or anything else blocking the vent may hinder the cooling efficiency of the appliance Vacuum the vent if necessary Vacation Time Unplug the unit from the wall outle...

Страница 16: ...oor gasket does not seal properly The appliance has recently been disconnected for a period of time 4 hours are required for the appliance to cool down completely Temperature inside the appliance is t...

Страница 17: ...ildren as they are a potential source of danger Please ask your dealer or your local authority about relevant means of safe disposal Disposal of the appliance This appliance is subject to European Dir...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...an Appliances AS Postboks 61 1740 Borgenhaugen Norway T 47 815 69 117 post norcool no Please visit out website for operating installation instructions in other languages www norcool no Version 1 0 Nov...

Отзывы: