Operating Sequence-900 and 9100 Series

Auto Mode

When AUTO mode is selected, the operating control automatically selects the energy source using the following priority

scheme:

When 120 volt AC is available,  the refrigerator will operate on AC electric. If 120 volt AC is not available, the refrigerator

will switch to and operate in LP Gas mode. On 3-Way models, when neither 120 volt AC nor LP gas are available, the
refrigerator will switch to DC electric. DC electric operation is not as efficient as LP Gas or AC electric operation. DC electric
should not be used to initially cool refrigerator
; it should be used only when other modes are unavailable (for example; while
in transit). If no input source (i.e 120 VAC, 12 VDC, or LP Gas) is available, the refrigerator will cease operation.

During operation in AUTO mode, when a higher priority energy source becomes available, the operating controls will cease

using the current energy source and will switch to the higher priority energy source. For example, if AC electric becomes
available while refrigerator is operating in AUTO LP GAS mode, the refrigerator will switch to AUTO AC operation. If AC
power becomes available and is found to be non functional or out of tolerance, the control will revert to the lower-priority
source.

Manual Mode

To operate in MANUAL mode, press and hold MODE button until word AUTO (900 Series) or the AUTO LED (9100

Series) disappears and desired operating mode is displayed. If energy source is interrupted while operating in MANUAL
mode, the corresponding fault indicator will appear, and refrigerator will cease operation until an alternate energy source is
selected or the problem is corrected.

AUTO and MANUAL Modes - Gas Operation Only

If gas does not ignite within 30 seconds, which may occur on initial start-up, the refrigerator’s gas valve will automatically

close and the operating controls will select an alternate energy source ( AUTO Mode) or, MANUAL mode, will revert to a
stand-by mode in which a fault indicator will appear. The fault indicator will remain until operating controls are turned OFF
and then ON again. If gas does not ignite after several attempts, refer to "Diagnostic" and "Trouble Shooting" sections for
corrective actions. A different mode of operation may be selected by pressing and holding MODE button. The refrigerator
will not switch to new operating mode until the MODE button is released.

LP GAS Mode Operation

When operating in LP Gas mode, the control opens the gas valve and sends a spark to the burner to ignite flame. The ignition

cycle is carried out as follows.

1. The gas valve is opened and spark output is activated for 1 second.
2. The spark output is de-activated and flame sense circuit is monitored. If there is no flame 1 second later,

spark output is re-activated.

3. Steps 1 and 2 are repeated until 30 seconds have elapsed, or until a flame is sensed during Step 2.

If burner fails to ignite, the control will turn off gas valve, lock out LP GAS mode, and display appropriate fault code. With

3-Way models operating in AUTO LP GAS mode, the control will automatically switch to DC Electric (heater) mode. While
operating in DC Electric mode, the appropriate fault indicator will be displayed. If DC voltage is available to refrigerator but
is below specification, the appropriate fault indicator will be displayed.

If the flame goes out, the control attempts to re-ignite flame, beginning with a new 30 second ignition trial. There is no limit

to the number of times flame can be lost and re-ignited.

If the control is displaying a fault indicator, pressing MODE button will disable the indicator and re-initiate 30 second trial

for ignition. During 30 the second time interval, an alternate mode of operation can be selected by pressing the MODE button.
When control measures input voltage below 10.5 VDC, gas operation is locked out.

Back-Up Operating System (BOS)

The refrigerator’s operating controls feature a Back-Up Operating System which provides a means for the refrigerator to

cool in the event of a temperature sensor failure. Once the BOS mode is entered, the temperature sensor is ignored and the
control displays a fault indicator. This mode provides adjustable cooling until the refrigerator is serviced. Norcold recommends
the refrigerator owner seek service as soon as practical to restore normal operation.

6

Содержание 9162

Страница 1: ...s 900 Series 7 Flashing LEDs 9100 Series Diagnostic Indicators 11 Diagnostics Fault Indicators 900 9100 Series 13 Step by Step Trouble Shooting 15 Internal Control Information 900 Series 19 Internal C...

Страница 2: ...ion that may result in property damage personal injury or death Use extreme care when working with or near a propane gas system Do not smoke or create sparks Do not use an open flame to check supply p...

Страница 3: ...autions and warnings before servicing refrigerator It is critical that the refrigerator installation is in accordance with Norcold s recommended procedures which are in compliance with standards for R...

Страница 4: ...4 17 32 x 21 19 32 38 5 8 x 21 19 32 14 17 32 x 21 19 32 31 5 8 x 21 19 32 14 17 32 x 21 19 32 31 5 8 x 21 19 32 Supply Voltage Requirements DC AC 15 4 Max 10 5 Min 132 Max 108 Min 15 4 Max 11 5 Min 1...

Страница 5: ...Control Voltage 3 Amp Blade Type AC Circuit 5 Amp 3AG Glass DC Control Voltage 3 Amp Blade Type AC Circuit 5 Amp 3AG Glass DC Electric Heater 30 Amp Blade Type DC Supply Wire Requirements Min Wire Siz...

Страница 6: ...erator will not switch to new operating mode until the MODE button is released D TEMP SET Button The TEMP SET thermostat button controls refrigerator and freezer temperature Press and hold TEMP SET bu...

Страница 7: ...ols are turned OFF and then ON again If gas does not ignite after several attempts refer to Diagnostic and Trouble Shooting sections for corrective actions A different mode of operation may be selecte...

Страница 8: ...ll will be active Controls will not switch to another energy source Refrigerator will cease operation MANUAL MODE 3 Way Model Alarm flashing backlight and bell will be active Controls will not switch...

Страница 9: ...AUTO MODE 2 3 Way Models Alarm flashing backlight and bell active Operating controls will not switch to next energy source Refrigerator will cease operation MANUAL MODE 2 3 Way Models Alarm flashing...

Страница 10: ...n be manually switched and operated in either the AC electric or LP Gas mode C4 3 Way Models Only DC Heater Failed Open DC voltage is being supplied to the heater but the heater is not drawing current...

Страница 11: ...energy source is manually selected C8 AC Heater Failed for Current Out of Tolerance AUTO MODE 2 3 Way Models No alarm flashing backlight or bell will be active Operating controls will not switch to or...

Страница 12: ...ashing AC LED All Models LED will flash pause flash pause etc Fault external to refrigerator controls AC mode selected AC power not available Flashing AC LED All Models LED will flash flash pause flas...

Страница 13: ...enters this mode the thermistor is ignored and the refrigerator will interpret the thermostat setting as a duty cycle command All LED s Flashing All Models LED s will flash pause flash pause etc AC h...

Страница 14: ...ontrols AC mode selected AC power not available See Section 4 on Page 16 A5 Flashing AC LED flash flash pause flash flash pause etc Fault external to refrigerator controls AC input voltage too low See...

Страница 15: ...ll LED Flashing flash pause flash pause etc AC Heater Failed Open See Section 14 on Page 18 C7 All LED Flashing flash pause flash pause etc Flame Circuit Failure See Section 15 on Page 18 C8 Not appli...

Страница 16: ...If the 3 amp fuse continues to blow disconnect the light wires from the light bracket Start refrigerator If fuse does not blow replace light bracket If fuse blows replace con trol board Caution A circ...

Страница 17: ...n Failure During Normal Gas Operation Corrective Action 1 Has LP gas tank been filled recently Purge gas line to refrigerator 2 Is LP gas tank valve on Turn valve on 3 Is refrigerator s manual shut of...

Страница 18: ...e connections if loose 3 Check vehicle s battery charging equipment Correct charging equipment Section 8 DC Input Voltage too High See Internal Control Information Corrective Actions 1 Check input DC...

Страница 19: ...ense electrode wire for continuity Replace if no continuity found 3 Check the sense ignition wire for short to ground Any reading replace sense ignition wire 4 Check ignition wire connection at power...

Страница 20: ...display panel The 9100 series internal information is communicated through the 9 temperature LED s The Internal Control Information mode can be exited by pressing the MODE and TEMP SET buttons simult...

Страница 21: ...uction divider heater D When operating in the LP GAS mode when this bar is illuminated it signifies the power board is providing ignition spark to the burner E When operating in the AC Electric mode w...

Страница 22: ...d this bar signifies that the fresh food compartment door has been opened for more than 2 minutes E All modes of operation When illuminated this bar signifies that the control s temperature sensing ci...

Страница 23: ...displayed on Screen No 4 should rise 3 If the temperature does not fall and rise when performing steps 1 and 2 replace the thermistor Screen No 5 AC Electric Input Voltage This screen displays AC inp...

Страница 24: ...2 9 Amps The current will be 10 of the control s display This screen displays the measured DC decimal point is implied input voltage to the control A Identifies information screen B The refrigerator c...

Страница 25: ...icable 2 Not Applicable 3 All modes of operation LED on signifies the fresh food compartment door is closed and the interior light is off 4 LP GAS mode LED on signifies a burner flame present at the b...

Страница 26: ...rrent operating mode is BAT TERY DC electric Screen No 3 Fin Temperature Sensed by Thermistor The thermistor is mounted on the 11th cooling fin from the right and monitors the refrigerator cabinet tem...

Страница 27: ...uld be 10 VAC of control display 2 Measure output voltage of the control board to AC heater Voltage should equal input volt age measured in Step 1 Screen No 5 AC Heater Current This screen displays AC...

Страница 28: ...To verify Measure the input DC voltage at control board The voltage will be 1 0 VDC of the control s display Screen No 7 DC Heater Current 3 Way Models Only This screen displays DC heater current mea...

Страница 29: ...he LED s off If any LED remains on replace power board Screen No 9 This screen verifies that all LEDs are functioning If any LED fails to light replace either the display panel or the power board See...

Страница 30: ...cooling system specification of 3 degrees off level side to side and 6 degrees off level front to back can cause irreparable damage to cooling system and can create a risk for personal injury or prope...

Страница 31: ...nt solution can cause severe burns to the eyes or skin and can ignite and burn with intense flame Sodium chromate contains chromium Certain chromium compounds can cause cancer by inhalation Do not cut...

Страница 32: ...C is not present check A Connection of the gas valve wires at the power board Secure if loose B Continuity of the gas valve wires Replace gas valve wires if no continuity C If 12 volt DC is not presen...

Страница 33: ...the flare nut and remove the burner tube from the orifice To prevent damage to the gas line use two wrenches when loosening the flare nut 5 Carefully remove the gas tube from the burner 6 Remove the o...

Страница 34: ...d the cooling system s flue tube must be cleaned at least once a year and after all prolonged seasonal shut down periods Follow Norcold s Ventilation and Installation recommendations explicitly and re...

Страница 35: ...own in Figure 32 1 Blue wire from power board connects to terminal 7 of DC module 2 Red wire from power board connects to terminal 9 of DC module 3 Black wire connected to refrigerator chas sis connec...

Страница 36: ...35...

Отзывы: