Physical Connections 

 

Remove WHT wires from interrupter. 

Insulate and set aside. 

 

N.O

12VDC 

Relay 

(coil polarity is unimportant) 

Содержание 3163 Series

Страница 1: ...electrical circuits that can lead to a dangerous situation it is recommended you proceed with caution No liability can be assumed for the use of these instructions To continue with these instructions...

Страница 2: ...om grill beneath the fridge door looking toward the left rear corner you should be able to see the blue burner flame through a small glass window on the front of the burner box See image below You can...

Страница 3: ...panel and set that panel aside 6 Unclamp and cautiously remove the hose from the barbed fitting on the bottom of the sink faucet If the faucet is made of plastic be very gentle twisting the hose loos...

Страница 4: ...the side flanges of the fridge on either side of the door 13 Tape the door locking pin on the chain to the cabinet to keep it out of the way 14 Ensuring that all front screws are removed gently pull...

Страница 5: ...ting on exposed metal or wires Set the wires aside on the floor 19 Pull the fridge completely out of the van and place it on a work surface It doesn t weigh much so you should be able to lift it easil...

Страница 6: ...y over the flame slots The tip must be over the flame for the maximum output voltage from the thermocouple The vibration of the van may have caused the thermocouple to slip back away from the flame re...

Страница 7: ...hread into the valve Why If you are brave you can attempt to rethread the valve s threads with the standard thread pitch or even riskier try to chase the threads on the valve with a new standard threa...

Страница 8: ...l next be lighting the burner Be sure to have plenty of ventilation though you will only be starting the burner momentarily Keep all flammable material away from the burner box 10 Press the Propane bu...

Страница 9: ...s a fix for this that eliminates the problem without replacing the relighter module The Fix The interrupter circuit inside the relighter module is supposed to go to zero ohms when the flame is detecte...

Страница 10: ...ket to go with above relays if you want to plug the relay into a socket instead of using female spade lugs plugged directly onto the relay s lugs Extra fluff 6 US online Any of the other 12VDC relays...

Страница 11: ...Page 11 of 15 Propane button Wiring Diagram N O 12VDC Relay coil polarity is unimportant...

Страница 12: ...Page 12 of 15 Physical Connections Remove WHT wires from interrupter Insulate and set aside N O 12VDC Relay coil polarity is unimportant...

Страница 13: ...Page 13 of 15 Final Drawing and Suggested Wiring Details from Paul Gloger Wiring colors above are suggested for ease of identification but other colors may be substituted...

Страница 14: ...16 20 AWG automotive wire is sufficient Color is not important exercise your own creativity 6 Make sure all connections are insulated covering with electrical tape if necessary Fasten the relay to the...

Страница 15: ...5 or the 6 o clock position This should bring the inside of the fridge to approximately 40 deg F 4 4 deg C 24 Change to 12V mode and ensure the inside temp stays at or lower than 40 degrees 25 Change...