The factory settings are as follows:
PARAMETER DESCRIPTION
PRESET VALUE (By default)
RANGE
ALU
High temperature alarm setting
C : 6°C F : -12°C
« ALL » value to 150°C
ALL
Low temperature alarm setting
C : 0°C F : -25°C
-50°C to « ALU » value
Ald
Temperature alarm delay
45
0 — 255 (min)
LHt
Light timer, start after door closing
5
0 — 255 (min)
doA
Door open alarm delay (timer start after
door opening)
15
0 — 255 (min)
Ot
Temperature probe calibration
0
-
12°C à 12°C
ALARM MESSAGE DESCRIPTIONS
MESSAGE
MODE
CAUSE
P1
Flashing
Probe failure
PoF
Flashing (3s)
Keyboard locked
Pon
Flashing (3s)
Keyboard unlocked
HA
Alternated with temperature
High Temperature Alarm
LA
Alternated with temperature
Low Temperature Alarm
dA
Alternated with temperature
Door open Alarm
EA
Alternated with temperature
Panic Alarm (Message and gray signal alarm ) Or
Fan failure alarm (message only)
Pan
Alternate with temperature
Serious external Alarm