3
KEYPAD OPERATION
Press 1 second to activate the module. Press 5 seconds to disable the mode. The message OFF is displayed on
the screen when the module is disabled.
Switch ON and OFF the light fixture.
Press to see the HIGH Temp ALARM setting (ALU parameter).
Press for 3 seconds to enter a new value for the HIGH Temp ALARM (ALU displayed), then press the Up-Down
Buttons for proper setting and then press the Set button to confirm and exit.
Press to see the LOW Temp ALARM setting (ALL parameter).
Press for 3 seconds to enter a new value for the LOW Temp ALARM (ALL displayed), then press the Up-Down
Buttons for proper setting and then press the Set button to confirm and exit.
Press to increase the displayed value, in programming mode.
Press to mute the local buzzer when an ALARM occurs.
Press to decrease the displayed value, in programming mode.
Press for 3 seconds to lock the keyboard (The ''POF'' message will be displayed).
Press for 3 seconds again to unlock.
Silencing buzzer
Once the alarm signal is detected, the buzzer can be muted by pressing the
key.
The alarm message and the 120V message will be displayed until the alarm condition is reset.
PARAMETERS SETTING
1.
Enter the Programming Mode by pressing the
keys for 3 seconds and the LED
will start blinking.
2.
Select the required parameter by using the
keys.
3.
Press the
key to display its value (now only the LED
is blinking).
4.
Use
to change its value
5.
Press
to store the new value and move to the next parameter.
To exit: Press
or wait 15 seconds without pressing a key.
NOTE: The set value is stored upon its recording, even when the procedure is not completed by exiting the configuration menu.