PAGE 5 OF 16
ISSUE 1
09 2005
Figure 1
3. If running the tool with oil, check the oil level in the lubricator and fill to the correct level if required. (see
MAINTENANCE section)
TIP. These tools have been designed to run with a clean, dry, unlubricated air supply if required, but this
is not essential. It is best to run a tool with unlubricated air from new as this avoids early oil
deposits solidifying and clogging the vane slots.
4. Fit reaction plate (D) over drive square to engage reaction splines. Fit circlip (#26486) supplied.
5.
Fit lifting bracket (E) into two holes in the side of the handle.
NOTE:
LIFTING BRACKET SECURING SCREWS MUST BE TORQUED UP TO 5 N.M.
TIP. The hanger should be used only in conjunction with a suitable balancer. If the tool is to be used
without a balancer or hanging device there is no need to fit the hanger to the tool.
Содержание PTM-72 Series
Страница 2: ......