![Norac UC4+ SPRACOUPE 4000 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/norac/uc4-spracoupe-4000-series/uc4-spracoupe-4000-series_installation-manual_1700479016.webp)
13
4.5
H
YDRAULIC
I
NSTALLATION
WARNING!
The hydraulic system creates very high
pressure. Before disconnecting any
hydraulic lines ensure all pressure has
been bled from the system. When
changing the boom hydraulic hoses leave
the booms in TRANSPORT POSITION.
IMPORTANT:
Component failure due to oil
contamination is not covered under the
UC4+ Spray Height Control system
warranty. It is recommended that a
qualified technician does the hydraulic
installation.
4.5.1
Valve Assembly
1.
On a clean surface remove all plastic plugs
from the NORAC hydraulic Valve (
V01
)
(
Figure 14
).
Figure 14 – NORAC Valve Block
2.
Install the orifices (
F05
) into the "B" ports
with the notch facing outward
as shown
in
Figure 15.
An O-ring pick can be used
to ease installing the orifices into their
locations.
3.
Install the orifices (
F05
) into the "A" ports
with the notch facing inward
.
4.
Install the 6MB-6MJ fittings (
F03
) into the
“A” and “B” ports and tighten to 18 ft-lbs.
Figure 15 – Valve Block Assembly