19
8
Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC
UC4.5 system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
8.1
Valve Assembly
1.
On a clean surface remove the plastic plugs from the block.
2.
Install two 6MB-6MOR (F02) fittings on the “P” and “T” ports on the NORAC block.
Tighten to 18 ft-lbs (24 Nm).
3.
Insert the orifices (F08) into the “B” ports.
4.
Install the 6MB-6MOR (F02) fittings into the “B” ports on the NORAC block. Tighten to
18 ft-lbs (24 Nm).
5.
Install the 6MBP plugs (F01) into the “A” ports of the NORAC valve block and tighten to 18
ft-lbs (24 Nm).
Figure 19: NORAC Valve Block Details
Содержание NITRO
Страница 1: ...NITRO Miller Technologies 90 120ft Boom Installation Manual NT3 ...
Страница 6: ...3 3 Kit Parts 3 1 Kit Overview Figure 2 NT3 System Parts ...
Страница 7: ...4 3 2 Hydraulic Plumbing Figure 3 NT3 Hydraulic Plumbing ...
Страница 27: ...24 10 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT 10 4 ITEM C04 44651 CABLE VALVE EXTENSION ...
Страница 28: ...25 10 5 ITEM C05 43210 20 CABLE UC5 NETWORK 18 AWG 20M 10 6 ITEM C06 43210 15 CABLE UC5 NETWORK 18 AWG 15M ...
Страница 29: ...26 10 7 ITEM C08 43220 03 CABLE UC5 NETWORK 14 AWG 3M ...
Страница 30: ...27 10 8 ITEM C10 44650 58 CABLE UC4 5 POWER NITRO ...