When you are not using the Stem 
Master, it should be stored in the 
original case supplied.  This helps 
to avoid damage to the Stem 
Master whilst it is not in use.

1)  Clean the Stem Master 

(following instructions in  
section 5).

2) Remove the handle grip by 

twisting it in a clockwise 
direction and pulling it down to 
release. 

3) Remove the piston, by applying 

a small amount of downward 
pressure on the calibration dial. 
Detach the piston from the 
keyhole slots in the side arms 
and pull the piston from the 
main body of the Stem Master. 
Then remove the spring from the 
piston.

4) Wash and rinse the piston and 

spring, then allow to dry.

5) Once dry, smear a very small 

amount of liquid paraffin or 
castor oil onto the piston  
and spring, in order to keep the 
parts lubricated.

6) Replace the spring onto the 

piston and, with the trigger in 
the open position, reattach the 
piston to the main body.  Secure 
it by fastening the keyhole slots 
in the side arms.

7) Reattach the handle grip by 

pushing it onto the piston 
assembly unit and secure in an 
anti-clockwise direction.

8) Ensure the calibration dial is set 

to the 1mm position.

9) Store in the case supplied.

 section 6:  storing

11

Содержание Stem Master

Страница 1: ...Safe and effective control of invasive weed species Instructions stemmaster...

Страница 2: ...aster for Use Personal Protective Equipment PPE 6 Connecting the needle 6 Filling the bottle with herbicide 6 Checking for leaks 7 Priming 7 Calibrating 8 Section 4 Operating the Stem Master 9 Section...

Страница 3: ...ted dose of herbicide directly into the stem of the weed We have designed the Stem Master to be robust and easy to use It is supplied in a hard case for easy and safe storage when not in use The Stem...

Страница 4: ...Section 2 Component List 1 Two needles with guard 2 Trigger 3 Handle grip 4 Piston assembly 4...

Страница 5: ...5 Bottle 6 Air Intake Valve 7 Allen Key 8 Grease 5...

Страница 6: ...secure it by tightening the grub screw on the guard Smear a light coating of silicone grease on the end of the needle where the o ring is located Loosen the three grub screws on the needle adaptor In...

Страница 7: ...ster in an upright position and check carefully for any leaks around the bottle trigger and air intake hole If a leak is found Bottle tighten the bottle cap Air intake hole remove the bottle decant th...

Страница 8: ...s into place in 1 ml increments To increase the amount of herbicide applied turn the calibration adjustment dial in a clockwise direction To reduce the amount of herbicide applied turn the calibration...

Страница 9: ...n the stem to escape Squeeze the trigger and the calibrated amount of herbicide will be delivered into the stem cavity Releasing the trigger automatically reloads the Stem Master with the calibrated h...

Страница 10: ...ndle grip by twisting it in a clockwise direction and pulling it down to release Immerse the Stem Master in soapy water without the bottle and the handle grip attached Whilst the Stem Master is in the...

Страница 11: ...the piston from the main body of the Stem Master Then remove the spring from the piston 4 Wash and rinse the piston and spring then allow to dry 5 Once dry smear a very small amount of liquid paraffin...

Страница 12: ...the instructions above The Stem Master contains intricate components which if lost broken or incorrectly replaced will render the unit inoperable and invalidate the warranty If the Stem Master is not...

Страница 13: ...We recommend the Stem Master is serviced by Nomix Enviro on an annual basis Section 7 Servicing 13...

Страница 14: ......

Страница 15: ......

Страница 16: ...Frontier Agriculture Ltd The Grain Silos Weyhill Road Andover Hampshire SP10 3NT T 01264 388050 F 01522 866176 E nomixenviro frontierag co uk www nomix co uk Use herbicides safely Always read the lab...

Отзывы: