background image

6

598-1285-00

aDJuStMent OF COveraGe area

The sensor on this light fixture detects “motion” 

by  the  movement  of  heat  across  the  coverage 

area. However, following are examples of objects 

that also produce heat and can cause the sensor 

to trigger:

• Pools of Water  • Air Conditioners

• Dryer Vents 

• Animals

• Heating Vents  • Automobile Traffic

If you suspect that a heat source of this type is 

triggering the sensor, reduce the sensitivity.

SPeCiFiCatiOnS

Range ............................................. Up to 30 ft. (9.1 m) [varies with surrounding temperature].

Sensing Angle................................. Up to 150°, 240° adjustable

Electrical Load ............................... Up to 100 Watt Maximum Incandescent

Bulb Type ....................................... Medium Base, Type “A”, 100 Watt Maximum

Sensor Capacity .............................. Up to 500 Watt (4.1 A) Maximum

Power Requirements ....................... 120 VAC, 60 Hz

Operating Modes ........................... TEST, AUTO, and MANUAL MODE

ON-Timer ...................................... 1, 5, 10 minutes

Test Timer ...................................... 5 Seconds

Manual Mode Timer ...................... Dusk-to-Dawn

MANUAL MODE

AUTO

TEST

ON-TIME Switch at 1, 5, or 10 

minutes

MODe SWitCHinG SuMMary

Flip  light  switch  off  for 

one  second  then  back 

on*

* If you get confused while switching modes, turn 

the power off for one minute, then back on. After 

the calibration time the control will be in the AUTO 

mode.

Содержание Carriage Light with Motion-activated Sensor 52-4477-8

Страница 1: ...er Wire Path Junction Box Screws Fixture Screw Horizontal Junction Boxes Only Removegroundscrewand2fixturescrewsfrom the mounting plate Flip plate over Reinsert ground screw Insert the 2 fixture screw...

Страница 2: ...Dwire unlessyouwanttocontrolotherlightsfrom the motion sensor see Optional Wiring Note All wiring must be run in accordance with the Canadian Electrical Code through conduit or another acceptable mean...

Страница 3: ...nd connect to the standard light s black wire Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 1 A Wiring Diagram 2 When wiring to control another motion sensing ligh...

Страница 4: ...ghtendecorativenutsremovedinstep 1 of Installation section securely against fixture base Mounting Screw Decorative Nut 3 Install one medium base light bulb 100 Watt maximum 4 If applicable place top c...

Страница 5: ...towards it and more sensitive to motion across coverage area Sensor Motion OPERATION Mode On Time Works Day Night Test 5 Seconds x x Auto 1 5 or 10 Minutes x Manual To Dawn x back on 1 Second OFF the...

Страница 6: ...9 1 m varies with surrounding temperature Sensing Angle Up to 150 240 adjustable Electrical Load Up to 100 Watt Maximum Incandescent Bulb Type Medium Base Type A 100 Watt Maximum Sensor Capacity Up t...

Страница 7: ...desired area Lightscomeonin daylight 1 Light control may be installed in a relatively dark location 2 Light control is in TEST 1 The fixture is operating normally under these condi tions 2 Set contro...

Страница 8: ...mations sous garantie Num ro de mod le Mod le 52 4477 8 Bo tes de jonction horizontales seulement Retirer la vis de mise la terre et les 2 vis de l appareildelaplaquedemontage Retournerla plaque Repla...

Страница 9: ...Deux lanternes d tecteur de mouvement Noir Blanc Vert ou d nud Noir Blanc Vert ou d nud Branchezlesfilsduluminaireauxfilsdanslabo te de raccordement Torsadez ces fils ensemble puis ajoutez y un conne...

Страница 10: ...blage2 C blaged unautreluminaire d tecteurdemouvement Ma tre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de com mande ma tre aux fils rouge et noir du lumina...

Страница 11: ...e queue d corativeoptionnel installezl croud coratif au bas du luminaire maintenant Ensemble facultatif S il y a lieu installer la queue d corative comme illustr ci dessous 1 Vissez l crou hexagonal a...

Страница 12: ...plus sensible aux mou vements traversant la zone de couverture Capteur Mode Temps en circuit En fonction jour nuit Essai 5 secondes x x Auto 1 5 ou 10 min x Manuel au choix amanecer x Le moins sensibl...

Страница 13: ...ussidelachaleuretpeuvententra ner le d clenchement du capteur Piscine Appareil de climatisation vent de s cheuse Animaux vent de ventilation Circulation automobile Si vous croyez qu une source de chal...

Страница 14: ...1 La commande peut tre install e dans un endroit relativement sombre 2 La commande d clairage est en mode essai 1 Le luminaire fonctionne normalement dans de telles conditions 2 R glez le commutateur...

Страница 15: ...________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ___________________...

Страница 16: ...________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ___________________...

Отзывы: