NOMA 52-4075 Скачать руководство пользователя страница 2

2

598-1284-00

INSTALLATION

For easy installation, select an existing light operated 
by a wall switch for replacement.
For best performance, mount the fixture about 
8 feet (2.4 m) above the ground.

W

ire

 

the

 L

ight

 C

ontroL

For eave mount only:

Wall Mount

Eave Mount

For under eave installation, the sensor head must 
be rotated
 as shown in the next two steps for proper 
operation and to avoid the risk of electrical shock.

  Align the Light Control cover plate and the junction 

box holes. Secure with the mounting screws.

  If not installed on a weatherproof box or if an adaptor 

plate (not included) was used, 

caulk the wall plate 

and mounting surface with silicone.

M

ount

 

the

 L

ight

 C

ontroL

 Rotate the sensor head towards the clamp screw 

joint.

 Then rotate the sensor head clockwise 180° so the 

controls face down.

Control Switch

Joint Clamp

❒ 

Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from the factory setting. When screwing in the flood-
lamps, do not overtighten.

Keep  lamps  at 
least  1"  (25  mm) 
from the sensor. 

Avoid  water  damage  and 
electrical shock - keep lamp 
holders below horizontal.

Lock nuts

Black to 

Black

White to 

White

Gasket

❒ 

Drill  the  holes  needed 
to mount the backplate 
to the junction box.

❒ 

Turn power off at the fuse or circuit breaker.

❒ 

Remove the existing light fixture.

  Route the Light Control's wires through the large 

gasket hole.

  Connect the junction box wires to the Light Control 

wires.  Twist  together  and  secure  with  a  wire 
connector.

If  the  sensor  pops  out  of  the  ball  joint,  loosen  the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

Содержание 52-4075

Страница 1: ...OPERATION resets to Auto Mode at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second O...

Страница 2: ...screw joint Then rotate the sensor head clockwise 180 so the controls face down Control Switch Joint Clamp Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more th...

Страница 3: ...k through the coverage area noting where you are when the lights turn on Move the sensor head up down or sidewaystochangethecover age area Keep the sensor at least 1 2 5 cm away from the lamps Adjust...

Страница 4: ...continuously Lights flash on and off POSSIBLE CAUSE 1 A flood lamp is positioned too close to thesensororpointedatnearbyobjects that cause heat to trigger the sensor Reposition the lamp away from the...

Страница 5: ...omprend FONCTIONNEMENT Revient au mode automatique au lever du soleil PRIORIT MANUELLE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME ESSAI back on AUTOMATIQUE 1 Second OFF then Amener l interrupteur de temp...

Страница 6: ...fa on que les commandes soient tourn es vers le bas Commandes Vis De Blocage Ajusterlesporte lampesendesserrantles crousde blocage mais ne pas faire tourner les porte lampes de plus de 180 par rapport...

Страница 7: ...tion Jusqu 110 Charge lectrique Jusqu deux ampoules incandescentes pour un maximum de 300 W maxi mum de 150 W par sup port Alimentation lectrique 120 V CA 60 Hz Modes de fonctionnement Essai automatiq...

Страница 8: ...allum continuel lement L clairage cli gnote CAUSE POSSIBLE 1 Un projecteur est situ trop pr s du d tecteur ou point vers des objets etlachaleurd clencheled tecteur Repositionnez le projecteur loin du...

Отзывы: