NOMA 52-4075 Скачать руководство пользователя страница 1

598-1284-00

Security Light with
Motion-activated Sensor

Models 52-4075 / 52-4076

Features

•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Photocell keeps the lighting off during daylight hours.

Requirements

•  The Light Control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 

wired through a switch.

• 

Some codes require installation by a qualified elec-
trician. Please check the codes in your area.

•  This product is intended for use with a junction box 

marked for use in wet locations.

•  The backplate has knockouts so the sensor can be 

mounted on most junction boxes.

•  In some applications a universal adaptor plate may 

be needed. Adaptors are available at home centers 
and electrical supply stores.

Cover 

Plate

Light Control

Lamp Holders

Sensor

2 Wire 

Connectors

Gasket

4 Mounting 

Screws (2 sizes)

This package includes:

OPERATION

* resets to Auto Mode at dawn.

Note:  When first turned on wait about 1 

1

/

2

 minutes for 

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1 

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF 

then...

Put the ON-TIME switch in the 1, 5, 
or 10 minute position.

Put the ON-TIME switch on the bottom 
of the sensor in the TEST position.

Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.

Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.

Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  10 
position.

Move ON-TIME Switch to 

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off 

for one second then 

back on*

MANUAL MODE

AUTO

TEST

*  If you get confused while switching modes, turn the 

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

This  product  is  ENERGY  STAR

®

  compliant 

when used with 120 Watt bulbs.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x

Installation and Operating 

Instructions

Содержание 52-4075

Страница 1: ...OPERATION resets to Auto Mode at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second O...

Страница 2: ...screw joint Then rotate the sensor head clockwise 180 so the controls face down Control Switch Joint Clamp Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more th...

Страница 3: ...k through the coverage area noting where you are when the lights turn on Move the sensor head up down or sidewaystochangethecover age area Keep the sensor at least 1 2 5 cm away from the lamps Adjust...

Страница 4: ...continuously Lights flash on and off POSSIBLE CAUSE 1 A flood lamp is positioned too close to thesensororpointedatnearbyobjects that cause heat to trigger the sensor Reposition the lamp away from the...

Страница 5: ...omprend FONCTIONNEMENT Revient au mode automatique au lever du soleil PRIORIT MANUELLE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME ESSAI back on AUTOMATIQUE 1 Second OFF then Amener l interrupteur de temp...

Страница 6: ...fa on que les commandes soient tourn es vers le bas Commandes Vis De Blocage Ajusterlesporte lampesendesserrantles crousde blocage mais ne pas faire tourner les porte lampes de plus de 180 par rapport...

Страница 7: ...tion Jusqu 110 Charge lectrique Jusqu deux ampoules incandescentes pour un maximum de 300 W maxi mum de 150 W par sup port Alimentation lectrique 120 V CA 60 Hz Modes de fonctionnement Essai automatiq...

Страница 8: ...allum continuel lement L clairage cli gnote CAUSE POSSIBLE 1 Un projecteur est situ trop pr s du d tecteur ou point vers des objets etlachaleurd clencheled tecteur Repositionnez le projecteur loin du...

Отзывы: