background image

8

model no. 043-5116-4  |  contact us: 1-866-827-4985

Cleaning and Maintenance

Sa

fety Features

The power indicator light, located near the control panel, lights whenever the heater is 
plugged in. The heater is equipped with an automatic overheat protection device located 
inside the body of the heater. If the heater grill is obstructed, or if the heater gets too 
hot for any reason, the automatic overheat protection device will turn the heater off. To 
reset the heater, simply turn power off and unplug the heater for 10 minutes until it cools 
down, then plug in and restart the heater. Be sure that the heater is on a smooth, level 
surface with no obstructions. The heater is also equipped with a safety tip-over switch. 
This switch will shut the heater off if the heater is tipped over. It will reset when the heater 
is placed upright.

CLEANING

CAUTION – Before cleaning the heater be sure to disconnect power cord and allow the 
heater to cool completely. Clean the outside surface with a clean, damp cloth. Do not use 
harsh chemicals or abrasive cleaners. DO NOT IMMERSE THE HEATER IN WATER. Allow 
heater to dry completely before use.

REPAIR

DO NOT OPERATE THE HEATER WITHOUT THE GRILL IN PLACE. DO NOT USE THE 
HEATER IF IT HAS MALFUNCTIONED OR BECOME DAMAGED IN ANY WAY.

STORAGE

Keep original carton for storage of the heater. Coil and tie the power cord to avoid 
damage during storage.

Содержание 043-5116-4

Страница 1: ...DIGITAL BASEBOARD HEATER Instruction Manual model no 043 5116 4 Toll free 1 866 827 4985 IMPORTANT Please read this manual carefully before running this heater and save it for reference...

Страница 2: ...Low 3 Top Mounted Control Panel 4 Power Indicator Light 5 Caution Indicator Light 6 Safety Overheat Protection 7 Safety Tip Over Protection 8 Silent Operation 9 Dent Resistant End Panels Features 2 Sp...

Страница 3: ...nd ordinances This heater must be plugged in to a 120 V AC 15 A or larger circuit Do not plug anything additional into the same circuit If you have any questions whether your wiring is adequate consul...

Страница 4: ...circuit do not plug the heater into a circuit that is servicing other electrical needs OPERATING INSTRUCTIONS Plug the power cord into a wall outlet 120 V AC 60 Hz Connect heater to properly grounded...

Страница 5: ...lay 2 Power Indicator Light 3 Low Heat Indicator Light 4 High Heat Indicator Light 5 Mode Button 6 ON OFF Button 7 Caution Indicator Light 8 Temperature Indicator Light 9 Timer Indicator Light 10 Temp...

Страница 6: ...n both heat settings is the current ambient temperature TEMPERATURE UNITS To switch between Celsius and Fahrenheit units press the MODE button once The digital display will blink 3 times and then auto...

Страница 7: ...ng the MODE button and adjust the time displayed to 00H NOTE When the timer has reached its setting the timer indicator light will turn off and the heater will automatically turn off returning to the...

Страница 8: ...that the heater is on a smooth level surface with no obstructions The heater is also equipped with a safety tip over switch This switch will shut the heater off if the heater is tipped over It will r...

Страница 9: ...ay from traffic area and where it will not be tripped over 9 To disconnect heater turn controls to off then remove plug from outlet 10 Do not insert or allow foreign objects to enter any ventilation o...

Страница 10: ...h the wide blade of the plug to the wide slot and fully insert plug If the plug does not fit contact a qualified electrician Never use an extension cord DO NOT attempt to defeat this safety feature Do...

Страница 11: ...ip and materials Noma Canada agrees to replace a defective product within the stated warranty period when returned to the place of purchase with proof of purchase This product is not guaranteed agains...

Отзывы: