FILENAME2 will be downloaded and FILENAME2 will be made passive. An ONT reboot is
not required.
d. If
pland-cfgfileX=FILENAME3
and
dnload-cfgfileX= FILENAME 4
, the OLT reports an
error because the filenames are not the same.
e. Configure equipment interface
pland-cfgfile1=XMLXXXXXX1
and
dnload-cfgfile1
XMLXXXXXX1
Configure equipment interface
pland-cfgfile2=XMLXXXXXX2
and
dnload-cfgfile2
XMLXXXXXX2
Although the OLT permits the above two steps without reporting an error, Nokia does not
recommend executing them, because the ONT may exhibit unexpected behavior.
f. If
pland-cfgfileX=Auto
and
dnload-cfgfileX= Auto
The OLT will download the XML file from "sw-ctr-list" (
configure equipment ont sw-ctrl
)
E
ND OF STEPS
The ONT will distribute the configuration files to the different services based on the active indication
from the OLT and on the Nokia defined index.
The ONT automatically reboots to apply the configuration files. After the ONT reboots and reports
the active version, the OLT completes the file download procedure.
Operators must check the committed file from the OLT to verify whether the corresponding file has
been applied. If an error occurs, contact Nokia for support.
ONT configuration file over OMCI
ONT configuration file over OMCI
Nokia ONT
Review
Review
© 2021 Nokia. Nokia Confidential Information
Use subject to agreed restrictions on disclosure and use.
3FE-49546-AAAA-TCZZA
December 2021
152