Microphone
Audio faults 2
Is microphone
working?
Change microphone.
Is it working now?
Re-test
Set phone in LOCAL mode.
Use Phoenix "Baseband
Audio Control" and set the
following: Enable Tx, Enable
Rx, Select MIC1, Enable HF
only (differential ended). Talk
through microphone.
Measure MICB1
voltage from MICP
pads on bottom
connector. Is it -2.1V?
Check C195, R176,
R178. If okay, change
UEM.
Is signal going to UEM
at MICP and MICN at
L122 and C174?
If connection is OK at
C174 and L122, then
change microphone.
Is signal going out of
UEM at XEAR, pin 10
on bottom connector?
Check signal at R160.
If OK, change UEM.
Re-test
Audio faults 3
No
Yes
No
No
Yes
No
Yes
No
Yes
Yes