NPM-10
Troubleshooting Instructions RF
CCS Technical Documentation
Page 48
Nokia Corporation Confidential
Issue 1 03/2003
RF Control
Phoenix menu: Select Maintenance, Testing, RF Controls
It is meant to check the receiver or transmitter without going in a call. It works very
much like a call, but you have control via the PC, and not via the tester. The GSM850 TX
PA mode should be set to High.
If you want to tune at other channels than the default, then you must select it first in RF
control and then start the tuning.
Call Testing
If all tunings are done, and the phone TX and RX is working, a call is the ultimate test of
the phone.
Set the communications tester to manual test. Switch the phone to normal if it was in
local mode. Remember to have a test simcard in the phone.
After the phone has registered to the communications tester, a call can be made. It is
possible to let the phone answer via Phoenix. In the Autocaller (Maintenance Testing)
you can answer by ticking Answer when button pushed and then push the button.