Check difference of offset strap coil
- difference of measured values must be range of 320 to 420digit for both channels
Check Set/Reset pulses and VBridge voltage
- measure with oscilloscope
- S/R pulses and Vbridge voltages are active only during the measurement phase
Check measurement bridges output voltages
- Voltages referred to ground must be near 1.1V and difference signal 0.0V