Audio fault 3
Audio
fault 3
IHF
speaker
working ?
Set phone to local
mode with Phoenix
(audio control).
Set buzzer ON, vol "9"
and freq. to 1kHz.
Measure signal level from
IHF pads to GND.
Is it rectangular wave
from 0V to VBatt?
Check L186 &
L187 IHF PA
output lines.
Retest
Measure AC-level
C173 & C174
Is it ~200 mVp-p ?
Measure shutdown DC-
level from J150. Is it
1.8V?
Change new C-cover
IHF speaker or contact
springs fault
Retest
Change UPP
(D400)
Retest
Change
UEMEk
(D200)
Retest
Change IHF PA
(N150)
Retest