Install a G-2426G-B indoor ONT
Connect a UPS to a G-2426G-B ONT
Nokia ONT
3FE-49441-ABAA-TCZZA
June 2021
Issue 1
83
Figure 6-13 G-2426G-B ONT and PSI UPS
Battery
Mute
DC
System Status
Alarm silence
Cold start
Reset
UPS
connector
3-prong
AC plug
Output
connector
Molex DC cable
AC power cable
36155
The following figure shows an example ONT and UPS. The position of the connections may differ for each ONT model
3
Remove the back cover to expose the battery connectors.
Slide Battery pack onto Power Supply/Charger unit until the Battery Pack becomes fully flushed
with Power Supply/ Charger as shown in
Figure 6-14, “Battery pack onto Power Supply/Charger”
(p. 84)
.
You should hear a click when battery pack is fully seated.
The UPS can remain on the desk or be placed on the floor underneath the desk.
Two battery extensions are needed for 8 hours of emergency support calls. Four battery
extensions are needed for 24 hours of emergency support calls.
Install the UPS back cover in the bottom of the last battery module to protect the connectors to
additional batteries.