![Nokia E62 Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/nokia/e62/e62_service-manual_254187128.webp)
Steps
1. Cover the light guide (upper part of the A-Cover).
2. Start
Phoenix
.
3. Choose
File
→
Scan Product.
4. Choose
Tuning
→
Ambient Light Sensor Calibration.
Figure 36
Ambient Light Sensor Calibration
window
5. In the
Pull Up Resistor Calibration
pane, click
Start
, and
Write
.
6. In the
Ambient Light Sensor Calibration
pane, check the
Use default values only
check box, and click
Write
.
7. To end the calibration, click
Close
.