g
Note:
The band straps are not part of the delivery and must be ordered separately.
When selecting a location to mount the BTS, keep in mind the following:
•
Avoid mounting the BTS such that the antennas are blocked by other structures such
as walls. A direct line of sight to the area to be covered will provide the best
performance.
•
Keep other metallic mounting features as far away from all antennas as possible.
•
Keep cables routed and secured away from the LTE and Bluetooth antennas.
•
Remotely locating the Bluetooth antenna is not allowed.
•
Since only remotely connected antennas are supported, external lightning surge
protection must be added. For more information on remotely mounting antennas, see
section
.
If side clearance is less than screw driver length, the grounding cable needs to be pre-
installed. The minimum and recommended maintenance clearances are shown in
2: Flexi Zone Micro BTS (FWHR) maintenance clearances
Table 3
Flexi Zone Micro BTS (FWHR) maintenance clearances
BTS side
Minimum clearances
Recommended clearances
Front
50 mm (1.97 in)
500 mm (19.68 in)
Rear
35 mm (1.38 in )
(1)
35 mm (1.38 in )
(1)
Top
100 mm (3.94 in)
Height of the unit + 10 mm
(0.39 in)
Bottom
100 mm (3.94 in)
300 mm (11.81 in)
Left
10 mm (0.39 in)
(2)
10 mm (0.39 in)
(2)
Right
10 mm (0.39 in)
10/110 mm (0.39/4.33 in)
(3)
(1)
For wall and pole installations.
(2)
For horizontal pole installations the clearance must be at least 20 mm (0.78 in).
(3)
Depends on the screwdriver length.
Installing Flexi Zone Micro BTS
Installing and Cabling Flexi Zone Micro High Power
2x20 W BTS
18
DN09229011
Issue: 02