CONFIDENTIAL
18
(25)
NPE-4 6310/NPL-1 6310i
Repairhints
Customer Care Europe & Africa
Version 1.0 Approved
SCCE Training Group
Date 15.08.2002
©
NMP 2002
Checked
by:
SCCE Training Group
Approved by:
SCCE
Hookswitch problems
Sometimes not possible to release “incoming call”
No voice dial possible
When the headset HDC-9P is connected to the botton connector of NPE-4 and a call is coming in, often it is not possible to
release the call by pressing the hookswitch.
Often it is also not possible to initiate the voice call by pressing the hookswitch.
If one of the above mentioned problems occures, the changing of R175 can solve the problem.
Open the BB-shield and measure the resistor
R175=100k
Ω
Ω
Ω
Ω
.
If
R175=100k
Ω
Ω
Ω
Ω
,
change the resistor to
15k
Ω
Ω
Ω
Ω
.
(See pictue below).
Note! Up to HW-ID 06.01 there is a 100k
Ω
Ω
Ω
Ω
resistor. From HW-ID 06.02 the value has changed to 15k
Ω
Ω
Ω
Ω
.
For more information also see
SB 024
100kohm
15kohm