24/107
6.2.2 S1 Ring count
Command Response
<n>
values
Read
S1? <n>
000..255
The S1 command returns the number of rings (RING or +CRING result codes) counted after
the last MT call setup.
6.2.3 S2 Escape code character
Command Response
<n>
values
Set
S2=<n>
0..127
(default
43)
Read
S2? <n>
000..127
The S2 command specifies the character to be used in the escape sequence. The default
character is a plus sign. See also the +++ Escape command.
6.2.4 S12 Escape guard time
Command Response
<n>
values
Set
S12=<n>
0..255
(default
50)
Read
S12? <n>
000..255
The S12 command sets the guard time before and after the escape sequence. The value is
in fiftieths of a second (the default is one second). See also the +++ Escape command.
6.2.5 +++
Escape
During the online data state, it is possible to enter the online command state by giving three
identical characters (defined by S2register; the default is ‘+’) in a sequence. Before and after
the sequence, there must be a pause of at least the time defined by the S12 register. By
setting S12 to zero, an escape sequence detection can be disabled.