3 - Sense LWEU Series 

 

Installation 

These devices themselves don’t require any specific installation. They are portable instruments. Upon 
shipping, they are automatically registered to the NSnappy service and are ready for use. 

Connections

 

Sense LWEU-N series models use a LoRaWAN wireless connection to send the data to the 
cloud-based NSnappy service. For the LoRaWAN radio reception to work, an 

NSnappy Hub 4G 

LWEU-N

 gateway device needs to be installed on all sites where these instruments will be used. 

Please refer to the manual of the hub device for its installation instructions. 

Usage 

Please refer to the NSnappy user guides for complete instructions on preparing and using the 
NSnappy service for measuring with Sense LWEU-N series devices. 

In short, follow these steps to take a measurement with a Sense device to the NSnappy service: 

1.

 

Log in to your NSnappy service account. 

2.

 

Navigate to the 

Tasks 

view. 

3.

 

Either select 

Enter new measurement

 or start performing a task that contains entering 

a measurement result. 

4.

 

Turn on the device by briefly pressing its power button. 

5.

 

Blue LED light on the device starts blinking in bursts of two blinks. This means the device 
is searching for a wireless LoRaWAN connection. 

6.

 

When the device is connected to the NSnappy Hub device, the blue LED blinks steadily. It 
can take a few seconds to connect. Note that the device will turn off automatically after 3 
minutes to save the battery. If this happens, restart and reconnect the device simply by 
pressing its power button again. 

7.

 

Measuring results start updating on the screen in the NSnappy service. 

8.

 

Start measuring. Refer to model specific measuring instructions below. 

9.

 

When the reading has stabilized, press the power button on the device or click the 

Pick 

measurement

 button on the screen. This locks the measurement reading. 

10.

 

Enter possible additional information and signature to the NSnappy service and save the 
measurement / execute the task. 

11.

 

The measurement is ready and data is saved to the NSnappy service.

 

 

 

Содержание NSnappy Sense LWEU Series

Страница 1: ...3004891141 V4 16 3 2022 Firmware 1 0 1 0 User manual Sense LWEU Series...

Страница 2: ...h Sense IR 6 The reading only updates with a few second intervals 6 Specifications 7 Warnings 8 Trademarks 8 Manufacturer 8 Introduction Nokeval NSnappy Sense series measuring instruments are LoRaWAN...

Страница 3: ...iew 3 Either select Enter new measurement or start performing a task that contains entering a measurement result 4 Turn on the device by briefly pressing its power button 5 Blue LED light on the devic...

Страница 4: ...fore the first readings appear on the screen Measuring with NSnappy Sense IR Point the lens of the IR sensor directly towards the target object Measuring distance should be between 5 to 20 cm The smal...

Страница 5: ...sive cloth moistened with a mild detergent solution Be careful not to scratch the IR sensor s lens Do not use any abrasive devices or substances when cleaning Do not clean the device in a dishwashing...

Страница 6: ...could give incorrect readings The readings appear to be too high or too low with Sense IR 1 Make sure that you are pointing the lens directly to the target 2 Make sure that you are measuring from as c...

Страница 7: ...urement Sense IR Sensor Gradient compensated thermopile infrared temperature sensor with integrated optics Mesurement beam 12 practical measurement distance 5 20 cm Target emissivity Fixed 0 95 Measur...

Страница 8: ...ike in a parked car where temperature can rise to over 50 C The battery may overheat and cause fire or explosion hazard Read this manual carefully before using the device Only Nokeval authorized servi...

Отзывы: