![Nokeval FTR970-PRO Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/nokeval/ftr970-pro/ftr970-pro_user-manual_1699205020.webp)
Realtime
Channels
Other periodic
Sporadic
Unknown
20
Device processes data in 3 different ways, one of which is real time data buffer. This data buffer is
completely independent of other functions of the device. Real time data buffer preserves most recent
radio packets until PC-program has time to read them.
Data buffer has room for 90 packets. Menu has a setting called “Realtime” which dictates which kind
of data is saved to this buffer.
Table how data is saved to the real time data buffer depending on device type and settings.
Channels
Other periodic
Sporadic
Unknown
MTR260
Processed
Processed
MTR262/FTR262
Processed
Unprocessed
MTR264
Processed
Unprocessed
MTR265
Processed
Unprocessed
MTR165
Processed
Processed
FTR860
Processed
Processed
CSR260
Processed
Processed
Unprocessed
KMR260
Unprocessed
X
Unprocessed
Note! Cells in gray are not possible options.
Realtime submenu
Channels
Choose whether
channels
are saved in real time data buffer.
Channels
are devices whose IDs have been confi gured in the channel
table in menu and are of type which can be used as
channels.
See previous table.
Other Periodic
Choose whether devices, which could be
channels
but are not confi gured
in channel table in menu, are saved in real time data buffer.
Sporadic
Choose whether devices, which could not be
channels
, are saved in real time data buffer.
These devices are mostly kind of devices which send burst data when stimulated, and not periodi-
cally like the devices that can be classifi ed as
channels
. For these purposes the FTR970-PRO has
also so called burst trap buffer, which removes multiple copies of burst data.
Unknown
Choose whether devices which are unknown (those devices which are designed after FTR970-PRO
software version) are saved in real time data buffer.
REALTIME DATA BUFFER