ID8746  V9  22.5.2017 

Firmware versions 1.0-1.0  

 

 

 

 

 

 

 

 

 

      

 

Ovazone-Cell-Link-MTR-RS485-3G 

Manual 

 

 

Содержание 98372

Страница 1: ...ID8746 V9 22 5 2017 Firmware versions 1 0 1 0 Ovazone Cell Link MTR RS485 3G Manual...

Страница 2: ...2 Contents Introduction 3 Installation 4 Configuring the device 7 Usage 16 Maintenance 18 Troubleshooting 19 Specifications 20 Warnings 21 Trademarks 21 Manufacturer 21...

Страница 3: ...eliver the data of the radio network to the Ovaport service Each device including nodes and gateways has to be set with the same Ovanet network The Ovanet network number has to be chosen between 1 167...

Страница 4: ...lled vertically The base station is splash proof but the location has to be chosen in a way that will not expose it to water or hot steam Please note that the AC socket and the power supply are not sp...

Страница 5: ...RS 485 bus D1 pin The diagram below presents the connector pinout looking towards the base station s female connector The same pinout is valid for an opened male connector looking towards the termina...

Страница 6: ...S 485 bus cable should no more than 30 meters long The bus is bidirectional Only one device at a time can send data during which other devices listen Only one device connected to the bus is set as mas...

Страница 7: ...0 protocol SCL address 0 Programming connector The device has a 3PIN POL programming connector Use POL 3PIN adaptor to connect the DCS772 to the device The 3PIN POL programming connector can be connec...

Страница 8: ...t in subsequent registers or they have different data types multiple queries are needed Config Serial communication Overview Not used Results setting zero OK Incorrect settings Conf settings are incor...

Страница 9: ...us registers are bit data and the result will be either 0 or 1 Config Serial communication Query x Register Register address search info on this from the other device s manual Config Serial communicat...

Страница 10: ...e Modbus query In the Ovaport Measuring points settings the device address and this virtual ID must match each other Config Serial communication Query x Status Not used Results setting zero OK Incorre...

Страница 11: ...Timeout s 1 Query interval das 3 Queries 4 Overview Query 1 Query 2 Query 3 Query 4 Example of the Modbus settings for RMD681 Config Modbus Query 1 Slave 3 Register Type Input Register Register 0 Resu...

Страница 12: ...vider 10 Virtual ID 6 Status OK 26 8 Example of the Modbus settings for Eurotherm 2216e Config Modbus Query 4 Slave 1 Register Type Input Register Register 1 Results 1 Data type Sint 16 bit Divider Of...

Страница 13: ...13 Menu chart...

Страница 14: ...14...

Страница 15: ...able on request on support nokeval com Mon menu The monitor menu settings are menu settings are mainly for the manufacturer use and most of them are not explained in this manual Support for purpose of...

Страница 16: ...low GSM modem has 2G connection Blinks red GSM modem replies Registration denied Solid red GSM modem is unable to communicate with the internal processor SRV Off When there is no IP address Blinks yel...

Страница 17: ...low bars Following LEDs are turned off RS485 RF2 RF1 SRV GSM Will return to normal state automatically in 30 s F2 Long press of the multifunction button will trigger an OTA update if update is unsucce...

Страница 18: ...h a rubber casket It can be cleaned by wiping with a damp cloth The device is not meant to be immersed into water or other liquids Service If Bat LED indicates low battery voltage red see above BAT LE...

Страница 19: ...uccessful The battery level needs to be above certain level to start the search for the new firmware If the search will not start change the battery and try to find a place with a better GSM coverage...

Страница 20: ...ffered results Type Non volatile FLASH memory Capacity About 500 000 measurements Battery Type 2 pcs Type D batteries Backup running time About 5 days at 20 C temperature About 8 hours at 20 C tempera...

Страница 21: ...t or some other place like in a parked car where temperature can rise to over 50 C The battery may overheat and cause fire or explosion hazard Read this manual carefully before using the device Only N...