background image

NOJA-7343-03 

 

Ground Mount Kiosk (GMK-1000 Series) 

 

User Manual 

I

NSTALLATION

 

A cable pit must be built for the GMK.  A concrete base is recommended.  

 

M

OUNTING 

D

ETAILS

 

The GMK has 4 x 14mm diameter mounting holes which can be used for bolting the GMK to the ground. 

 

Содержание GMK-1000 Series

Страница 1: ...NOJA 7343 03 User Manual Ground Mounted Kiosk GMK 1000 Series www nojapower com au ...

Страница 2: ...Power Switchgear and the document or any part thereof should not be copied or reproduced in any form without written permission from NOJA Power Switchgear NOJA Power and OSM are registered trademarks of NOJA Power Switchgear and should not be reproduced or used in any way without written authorisation NOJA Power Switchgear applies a policy of ongoing development and reserves the right to change pr...

Страница 3: ...CABILITY 1 SAFETY 1 SPECIFICATIONS 2 RATINGS 2 IP RATINGS 3 DIMENSIONS AND WEIGHT 3 DRAWINGS 4 INSTALLATION 6 MOUNTING DETAILS 6 LIFTING POINTS 7 CABLE ENTRIES 9 DEAD BREAK ELBOWS 10 EARTH SADDLE 10 EARTH BAR 11 RECLOSER CONTROL RC10 CUBICLE 12 ...

Страница 4: ...ument provides the following information for the GMK Specification Drawings Installation Details For more details on the features provided by the RC 10 please refer to the OSM User Manual APPLICABILITY This manual covers the following product GMK15 16 1310 GMK27 12 1310 SAFETY Installation use and servicing should only be carried out by trained and experienced personnel who are familiar with the e...

Страница 5: ...12 5 kA Asymmetrical Breaking Current 17 kA 13 kA DC component Interruption capacity 20 20 Mechanical operations 30000 30000 Full Load Operations 30000 30000 Fault break capacity operations 70 140 Short time current withstand 3 seconds 16 kA 16 kA Mainly active breaking capacity 630 A 630 A Cable charging current 25 A 25 A Line charging current 5 A 5 A Impulse withstand across the interrupter 110 ...

Страница 6: ... Manual IP RATINGS The IP ratings are as follows IP65 for the controller compartment IP54 for the customer equipment compartment IP65 for the OSM310 GMK IP54 for the OSM Cable Compartment DIMENSIONS AND WEIGHT Dimensions 1225 x 1341 x 1160 mm Weight 480kg ...

Страница 7: ...NOJA 7343 03 4 Ground Mount Kiosk GMK 1000 Series User Manual DRAWINGS Note The GMK is supplied with a blank radio equipment tray Suitable mounting holes have to be drilled prior to use ...

Страница 8: ...ound Mount Kiosk GMK 1000 Series User Manual Note The manual trip ring is located in the customer equipment compartment next to the open close indicator window LV supply is through the gland plate on the partition wall ...

Страница 9: ...Kiosk GMK 1000 Series User Manual INSTALLATION A cable pit must be built for the GMK A concrete base is recommended MOUNTING DETAILS The GMK has 4 x 14mm diameter mounting holes which can be used for bolting the GMK to the ground ...

Страница 10: ...Series User Manual LIFTING POINTS Fork entry holes 140 x 50mm are available at the bottom of the unit as shown Where no forklift is available the GMK can be lifted through the lifting points welded on the enclosure body using slings and a crane ...

Страница 11: ...NOJA 7343 03 8 Ground Mount Kiosk GMK 1000 Series User Manual ...

Страница 12: ...ound Mount Kiosk GMK 1000 Series User Manual CABLE ENTRIES The GMK is supplied with blank aluminium gland plates for HV LV and Earth cable entries Holes must be drilled to suit the compression glands of incoming cables ...

Страница 13: ...nnector Installation of Dead Break Elbows is brand specific Please refer to the installation manual of the dead break elbow for detailed instructions For a generic guide refer to NOJA 7320 Dead Elbow Connector Installation Instructions Note Our supplied product which does not include termination such as dead break elbows is rated at 150kV BIL EARTH SADDLE The Earth Saddles are used to support eart...

Страница 14: ...ts are connected to earth through the earth bar located at the bottom of the recloser A cable entry has to be prepared on the HV gland plate to suit the incoming main earth cable which will be then connected to the earth bar The earth bar comes with M12 nut and bolt that can be used in connecting the main earth cable ...

Страница 15: ...NOJA 7343 03 12 Ground Mount Kiosk GMK 1000 Series User Manual RECLOSER CONTROL RC10 CUBICLE Please refer to the OSM User Manual ...

Отзывы: