NoiseMeters Limited CR800C Скачать руководство пользователя страница 8

Ordering Information 

 
 
The CR800C series can be ordered with a variety of features. The table below shows the Sound Level Meter  and Measurement Kit 
reference numbers:  
 

Instrument                  Measurement Kit                    Description

 

CR811C                        CK811C                                      CR:811C Class 1 Sound Level Meter 
CR812C                        CK812C                                      CR:812C Class 2 Sound Level Meter 
CR821C                        CK821C                                      CR:821C Class 1 Sound Level Meter with 1:1 Octave Band Filters  
CR822C                        CK822C                                      CR:822C Class 2 Sound Level Meter with 1:1 Octave Band Filters  
CR831C                        CK831C                                      CR:831C Class 1 Sound Level Meter with 1:1 & 1:3 Octave Band Filters  
CR832C                        CK832C                                      CR:832C Class 2 Sound Level Meter with 1:1 & 1:3 Octave Band Filters  
CR813C                        CK813C                                      CR:813C Class 1 Sound Level Meter  
 

Outdoor Measurement Kits 

CK408C                        Heavy duty Outdoor Measurement Kit for CR811C, CR813C, CR821C & CR831C 
CK508C                        Lightweight Outdoor Measurement Kit suitable for CR811C, CR813C, CR821C & CR831C 
CK408/811                   Complete Heavy duty Outdoor Noise Measurement Kit including CR811C & CR515 Acoustic Calibrator 
CK508/811                   Complete Lightweight Outdoor Noise Measurement Kit including CR811C & CR515 Acoustic Calibrator 
 
Options for the Outdoor Measurement Kits 
MM801C                       Factory fitted GSM Modem Option for Outdoor Measurement Kits with ZL:810 external 12v power cable 
ZL810                            External 12v Battery Power Connector for Outdoor Kits 
 

Factory Fitted Upgrades 

 
A range of options are available to enhance the performance of the CR800C series. These options can also be fitted when an instrument is 
returned for service and recalibration. These options include: 
 
MO800/1                       Factory upgrade from Class 2 to Class 1 
MO800/2                       Factory upgrade from Broadband to include additional 1:1 Octave Band Filters 
MO800/3                       Factory upgrade from Broadband to include additional 1:1 & 1:3 Octave Band Filters 
MO800/4                       Factory upgrade from 1:1 to 1:1 & 1:3 Octave Band Filters 
MO800/5                       Factory upgrade - Remote Preamplifier for Class 2 Instruments 
MO800/6                       Factory upgrade - Addition of 20Hz & 20kHz 1:3 Octave Band Filters to CR:832C or CR:831C  
 
 
 
A range of optional accessories are available for the CR:800C Series.  
 

Microphone Extension Cables                                               Output Cables 

ZL202 2m microphone extension cable                                  Standard:        ZL100 USB to USB 
ZL205 5m microphone extension cable                                  Optional:         ZL812 AC Output Cable to Phono Connector 
ZL210 10m microphone extension cable                                                          ZL813 RS232 Output Cable 
ZL215 15m microphone extension cable                                                          ZL814 Multi I/O Interface 
ZL:220 20m microphone extension cable  
 

Mains Power Supply 

CU800C Mains Power Supply. Specify UK, Eu or USA type plug.  

NoiseMeters Limited 

West End, Muston, North Yorkshire 
YO14 0ES, England 
 
Tel:          0845 680 0312 
Fax:         0845 680 0316 
 
Email:       [email protected] 
Web:        www.noisemeters.co.uk 

NoiseMeters USA 

14781 Memorial Drive, Suite #2174 
Houston, TX 77079, USA 
 
Toll Free:  888 206 4377 
Fax:         888 584 2230 
 
Email:       [email protected] 
Web:        www.noisemeters.com 

www.noisemeters.com                         www.noisemeters.co.uk                         www.noisemeters.eu 

Содержание CR800C

Страница 1: ...NoiseMeters Limited www noisemeters com CR800C Sound Level Meters www noisemeters com www noisemeters co uk www noisemeters eu ...

Страница 2: ...high performance Sound Level Meters that provide the functions and features demanded by modern measurement standards and guidelines while being designed specifically for ease of use From Noise at Work Risk Assessments to Vehicle Noise Testing to Environmental Noise Measurements the CR800C Series provides a solution Data logging of the measured parameters is standard and up to 12 days of data can b...

Страница 3: ...rotection Boundary noise measurements External noise impact assessments Machinery noise testing Motor sport noise measurements Entertainment noise For Environmental Noise measurements the measurements required differ from those for Occupational Noise and all of the CR800C instruments provide these parameters as standard The measurement of Lmax Lmin and five Ln values such as L10 L90 and L95 in add...

Страница 4: ...ment can be configured to store LIeq or LFTeq in place of LE The duration of the measurement can be either open ended selected from a preset lis t or defined by the user as required and the measurements can also be set to automatically repeat a specified number of times This function is essential for environmental noise applications where the required measurement duration may be 15 minutes repeati...

Страница 5: ... database can be freely downloaded online Measurement Reports The Deaf Defier software contains a number of simple preformatted measurement reports that can be used to present measurement data Information about the measurement such as the location time date and comments can be entered along with details of the calibration of the sound level meter When the report is complete the information can be ...

Страница 6: ...he microphone as well as a rechargeable battery pack to power the sound level meter The CK508C Lightweight Outdoor Kit has been designed to be used for short term measurements such as overnight whilst the CK408C Outdoor Kit has been designed for longer term use The Weatherproof case used for both of the outdoor measurement kits contains the same accessories included in the standard measurement kit...

Страница 7: ...Memory 1300 broadband measurements 770 1 1 octave measurements 330 1 3 octave measurements Eg 12 days of 15 minute broadband measurements stored Noise Profile LAeq LCeq or LZeq Short Leq LAeq LCeq or LZeq Up to 12 days at 1 second acquisition 2 second factory set option Automatic Measurements The unit can be set to record and store data over fixed times of 1 minute 5 minutes 10 minutes 15 minutes ...

Страница 8: ...are available to enhance the performance of the CR800C series These options can also be fitted when an instrument is returned for service and recalibration These options include MO800 1 Factory upgrade from Class 2 to Class 1 MO800 2 Factory upgrade from Broadband to include additional 1 1 Octave Band Filters MO800 3 Factory upgrade from Broadband to include additional 1 1 1 3 Octave Band Filters ...