NoiseMeters Limited CR800C Скачать руководство пользователя страница 4

General Noise Measurements 

>

R&D noise measurements 

>

Production line noise testing 

>

Quality control 

>

Sound power measurements 

>

Fire alarm testing  

The CR800C series can be used in a wide range of general noise 
measurement applications. 
 
The provision of Lmax allows the instruments to be used for the 
measurement of vehicle noise levels. 
 
Optional microphone extension cables enable the microphone and 
preamplifier to be located away from the Sound Level Meter 
allowing measurements to be taken in confined areas and in 
situations  where interference from the operator would affect the 
validity of the data. Product development and testing is an 
application where this feature is often essential. 
 
All of the CR800C instruments can provide an un-weighted AC 
output which can be used in conjunction with other noise 
measurement equipment and recording systems. This allows the 
units to be used for both general purpose noise measurements as 
well as more advanced applications.  

Measurements 

 
The CR800C series measure two different types of data, 
Broadband and Frequency.  
 
The Frequency data can be 1:1 Octave or 1:3 Octave depending 
upon the configuration of the instrument. In addition to the 
measured data, the instrument stores calibration records for later 
download. 
 

Broadband Measurements

 

 
The standard parameters stored by all of the CR800C series 
include Leq , Lmax , Lmin, LCPeak, LE and 5 Ln values. In addition 
to these standard measurements, the instrument can be configured 
to store LIeq or LFTeq in place of LE. 
 
The duration of the measurement can be either open-ended, 
selected from a preset lis t or defined by the user as required, and 
the measurements can also be set to automatically repeat a 
specified number of times. 
 
This function is essential for environmental noise applications 
where the required measurement duration may be 15 minutes 
repeating over a 24 hour period.  
 

Time History

 

 
When making a Broadband measurement, the instrument 
automatically stores a nois e profile, or Time History, with the 
measurement. This information is stored as a 1 second Short Leq.  
 
Over 12 days of Time His tory data can be stored, allowing the 
CR800C series to be used for logging long periods of data. 
 
This information can be used, for example, to analyse noise events 
and to identify individual noise sources, such as aircraft. When this 
data is downloaded into the Deaf Defier software, measurement 
reports can be created to display both the overall data and the 
Time History information.  
 

Frequency Analysis

 

 
When fitted with the 1:1 or 1:3 Octave Band filters, the CR800C 
series can provide a sequential sweep through the filter bands, with 
a minimum duration of 1 minute for the 1:1 Octave Band filters and 
3 minutes for the 1:3 Octave Band filters. The sweep can be 
automatic or manual as required. 
 
The 1:1 Octave Band filters cover the range of 31Hz to 16kHz, and 
the 1:3 Octave Band filters cover 25Hz to 16kHz. 
 
The MO800/6 option can be fitted to the 1:3 Octave Band filter to 
add a 20Hz and 20kHz filter band to the existing 1:3 Filter Bands.  

www.noisemeters.com                         www.noisemeters.co.uk                         www.noisemeters.eu 

Содержание CR800C

Страница 1: ...NoiseMeters Limited www noisemeters com CR800C Sound Level Meters www noisemeters com www noisemeters co uk www noisemeters eu ...

Страница 2: ...high performance Sound Level Meters that provide the functions and features demanded by modern measurement standards and guidelines while being designed specifically for ease of use From Noise at Work Risk Assessments to Vehicle Noise Testing to Environmental Noise Measurements the CR800C Series provides a solution Data logging of the measured parameters is standard and up to 12 days of data can b...

Страница 3: ...rotection Boundary noise measurements External noise impact assessments Machinery noise testing Motor sport noise measurements Entertainment noise For Environmental Noise measurements the measurements required differ from those for Occupational Noise and all of the CR800C instruments provide these parameters as standard The measurement of Lmax Lmin and five Ln values such as L10 L90 and L95 in add...

Страница 4: ...ment can be configured to store LIeq or LFTeq in place of LE The duration of the measurement can be either open ended selected from a preset lis t or defined by the user as required and the measurements can also be set to automatically repeat a specified number of times This function is essential for environmental noise applications where the required measurement duration may be 15 minutes repeati...

Страница 5: ... database can be freely downloaded online Measurement Reports The Deaf Defier software contains a number of simple preformatted measurement reports that can be used to present measurement data Information about the measurement such as the location time date and comments can be entered along with details of the calibration of the sound level meter When the report is complete the information can be ...

Страница 6: ...he microphone as well as a rechargeable battery pack to power the sound level meter The CK508C Lightweight Outdoor Kit has been designed to be used for short term measurements such as overnight whilst the CK408C Outdoor Kit has been designed for longer term use The Weatherproof case used for both of the outdoor measurement kits contains the same accessories included in the standard measurement kit...

Страница 7: ...Memory 1300 broadband measurements 770 1 1 octave measurements 330 1 3 octave measurements Eg 12 days of 15 minute broadband measurements stored Noise Profile LAeq LCeq or LZeq Short Leq LAeq LCeq or LZeq Up to 12 days at 1 second acquisition 2 second factory set option Automatic Measurements The unit can be set to record and store data over fixed times of 1 minute 5 minutes 10 minutes 15 minutes ...

Страница 8: ...are available to enhance the performance of the CR800C series These options can also be fitted when an instrument is returned for service and recalibration These options include MO800 1 Factory upgrade from Class 2 to Class 1 MO800 2 Factory upgrade from Broadband to include additional 1 1 Octave Band Filters MO800 3 Factory upgrade from Broadband to include additional 1 1 1 3 Octave Band Filters ...

Отзывы: