Table 2-3
Gas
Average (mg/m
3
)
Maximum (mg/m
3
)
SO
2
0.2
1.5
H
2
S
0.006
0.03
NO
2
0.04
0.15
NH
3
0.05
0.15
Cl
2
0.01
0.3
2.7 Power Supply
DC power adapter: 48V/0.3A
Specifications of Connector
Internal Diameter
External Diameter
Depth
Polarity
2.1mm
5.5mm
10mm
Internal: positive
External: negative
2.8 Installation Tools
Common Tools
Phillips screwdriver, related copper and fiber cables, bolts, diagonal pliers, cable ties
Special Tools
Wire stripper, crimping pliers, RJ-45 crimping pliers, punch down tool
Meter
Multimeter, bit error rate tester (BERT)
The listed tools are customer supplied.
2.9 Unpacking the Access Point
Package Contents
Items
Verify that all parts are installed and debugged.
Screws
Mounting brackets
Product quick installation guide
Packing list
The above listed items are for general situations, which may vary in the actual shipment. The purchase order shall
prevail in any case. Please check each item carefully according to the packing list or purchase order. If any item is
damaged or missing, notify the sales person.