background image

NX-5610-24F4G 

Core Aggregation Switch 

Product Guide 

Содержание NX-5610-24F4G

Страница 1: ...NX 5610 24F4G Core Aggregation Switch Product Guide ...

Страница 2: ... any portion of this document in any form or by any means is forbidden Statement of Exemption This material is being distributed as is This document s contents are subject to change at any time without notice Please visit the Nodexon Networks website for the most up to date information Nodexon Networks makes every effort to guarantee content accuracy but cannot be held liable for any losses or dam...

Страница 3: ...or cables and connectors Audience It is intended for the users who have some experience in installing and maintaining network hardware At the same time it is assumed that the users are already familiar with the related terms and concepts Obtaining Technical Assistance Website https www nodexon com Technical Support Website https nodexon com support Community http www nodexon com community Technica...

Страница 4: ...pter 1 Product introduction Briefly describe the basic functions and features of the switch detailed hardware and software specifications and appearance information Chapter 2 Hardware Connections Guide the connection and precautions between the switch and other devices Chapter 3 Product Installation Guide the hardware installation method and precautions of the switch Chapter 4 Product Packaging an...

Страница 5: ...n and core application scenarios in campus hotel and enterprise campus 1 2 product characteristics Full Gigabit Ethernet port 24 full Gigabit RJ45 network port and 4 X 10G SFP fiber interface 4 Gigabit RJ45 port Combo breaking the traditional fast limitation data transmission without blunt Broadcom high end chips can greatly enhance the network data processing rate Support DHCP server DHCP relay D...

Страница 6: ...nsole port 1 1000M RJ45 management port 1 USB 2 0 1 Mini usb Console port performance Forward mode store and forward Backplane bandwidth 128 Gbps Packet forwarding rate 95 2 Mpps Support 16 K MAC address table depth Lightning protection 6 KV ESD Contact 6K V air 8K V Input power 100 240V 50 60Hz ...

Страница 7: ...PFv1 OSPFv2 dynamic routing Support static routing DHCP Support DHCP server Support DHCP relay Support DHCP Snooping Support 4K VLANs VLAN Support 802 1Q VLAN MAC VLAN IP VLAN Voice VLAN MAC address table Follow the IEEE 802 1d standard Support MAC address automatic learning and aging ...

Страница 8: ...ss based on port number IP address and MAC address Support HTTPS SSL V3 TLS V1 SSH V1 V2 Support IP MAC PORT ternary binding Support ARP protection IP source protection DoS protection Support DHCP Snooping and DHCP attack protection Support 802 1X authentication AAA Support port security port isolation ...

Страница 9: ...iting QoS re marking Quality of Service QoS Support 8 port queues Support port priority 802 1P priority DSCP priority Support SP WRR W FQ priority scheduling algorithm Spanning tree Supports STP IEEE 802 1d RSTP IEEE 802 1w and MSTP IEEE 802 1s protocols Support loop protection root bridge protection TC protection BPDU protection BPDU filtering ...

Страница 10: ...ng packet statistics and unknown multicast discards Support for multicast suppression Storm suppression Support broadcast suppression Support for unknown unicast suppression Link aggregation Support static aggregation Support dynamic aggregation Support IP MAC hybrid load balancing mode Supports up to 32 aggregation groups ...

Страница 11: ...L V3 Support CLI Telnet SSH V1 V2 local serial port Management and maintenance Support for SNMP V1 V2 V3 Support LLDP RMON Support ARP protection IP source protection DoS protection Support CPU monitoring memory monitoring Support Apollo cloud platform one stop management and maintenance Support system log grading warning ...

Страница 12: ...s shown in the following table Indicator Light Name Colour Working Status Description PWR Power Indicator Red Constantly Bright Power On Normally Not Bright No Power Power Switch Is Not Turned On Power Supply Is Abnormal LINK A CT Device Connection Indication Green Flicker The Corresponding RJ45 Port Is Connected Normally Not Bright The Corresponding RJ45 Port Is Not Connected Properly ...

Страница 13: ...mbo 10 100 1000 Mbps RJ45 ports 1 RJ45 Console port and 1 Gigabit RJ45 management port SFP port NX 5610 24F4G provides four 10 Gigabit SFP port optical module expansion slots for plugging in Gigabit SFP modules RST button When the switch is powered on press the button with the needle and release the device to enter the restart state When the SYS light is turned on again the device restarts When th...

Страница 14: ...rminal Outlet Connect the power cable to the switch NX 5610 24F4G The power supply needs to be 100 240V 50 60Hz AC power Ground Terminal Use a wire ground to prevent lightning strikes To avoid product lightning strikes and extend the life of the product Chapter 2 Hardware connection 2 1 port RJ45 connection Connect the switch and the RJ45 port of the peer network device with a network cable ...

Страница 15: ...he status of the corresponding indicator If the indicator is on the link is up If the indicator is off the link is down Check the line and confirm that the peer device is enabled It is not allowed to excessively bend the fiber and its radius of curvature should be no less than 10cm Ensure the cleanliness of the fiber end face Please do not look directly into the fiber optic connector with your eye...

Страница 16: ... indicated by the switch Before powering on the switch please make sure that the power circuit is not overloaded so as not to affect the normal operation of the switch and cause unnecessary damage To avoid the risk of electric shock do not open the case while the switch is working even if it is not charged do not open it yourself Before cleaning the switch first pull out the power plug of the swit...

Страница 17: ...ty exceeds a certain intensity it will still cause fatal damage to the electronic components on the internal circuit board To avoid the static electricity affecting the normal operation of the device please pay attention to the following 1 Regular dust removal to keep indoor air clean 2 Make sure that the equipment is well grounded to ensure 3 the smooth transfer of static electricity Interference...

Страница 18: ...ommended to use a signal lightning arrester Installation Rack Requirements Regardless of whether the switch is installed in a rack or other horizontal workbench please note the following 1 Verify that the rack or table is stable strong and capable of withstanding a weight of at least 5 5 kg 2 Confirm that the rack itself has a good cooling system or keep the room well ventilated 3 Make sure the ra...

Страница 19: ... rack is an important guarantee for anti static anti leakage lightning protection and anti interference of the equipment Therefore ensure that the grounding wire of the rack is properly installed The equipment installed in the rack is generally from bottom to top to avoid overload installation Avoid placing other heavy objects on the surface of the switch to avoid accidents Ensure heat dissipation...

Страница 20: ...uter IP address to 192 168 254 X X is within 2 254 and the subnet mask is 255 255 255 0 Step3 Open the browser of the computer enter 192 168 254 1 in the address box and hit the Enter key Step4 Enter the web network management login page of the switch enter the default username and password admin in the username and password input fields and then click Login ...

Страница 21: ...e switch and can start to configure the switch Chapter 4 packing list and recommendations for use 4 1 Open the package and check the following list carefully article Quantity Description switch 1 power cable 1 Switch power supply Hanging ear 2 For rack mounting ...

Страница 22: ... prevent water from entering the fuselage through the casing resulting in damage to the machine 5 Please turn on the power after the line connection is completed 6 In the state of power on of the product please do not plug and unplug the cable at random 7 Do not use the switch in places with excessive dust and electromagnetic radiation Do not use the switch in a place with high temperature and no ...

Отзывы: