Nocchi R2SE Скачать руководство пользователя страница 4

8

1. General Safety Rules

These instructions are of fundamental importance for the installation, use and maintenance
of these products and must therefore be read before commencing work and then carried
out accurately by the installer and end user. Installation and maintenance must be carried
out by qualified personnel only. Failure to comply with these safety instructions will cause
risk to people and equipment and may invalidate the guarantee.

Identified hazards are highlighted by the following symbols: -

Danger from general causes: 

Danger from electrical causes: 

Instructions which if ignored could cause damage or impair the function of the pump are
highlighted by the word: 

ATTENTION

1.1 Field of Application

The range is suitable for open vented or pressurised domestic central heating systems only. 

1.2 Product Data

SR3 xx/40
SR3 xx/50
SR3 xx/60

SR3 25/70

R2SE

Connection Voltage

1~230V

±

10%, 50Hz

1~230V

±

10%, 50Hz

1~230V

±

10%, 50Hz

Insulation class

H(180

0

C)

H(180ºC)

F(155

0

C)

Temperature class

TF110

T110

TF95

Permitted fluid temperature

Dew point ~ +110

0

C

System of protection

IP44

-10

0

C ~ +110

0

C

+2

0

C ~ +95

0

C

IP44

IP42

Weight

2.9Kg

(6.5lbs)

3.5Kg

(7.7lbs)

2.4Kg

(5.3lbs)

Normal operating flow rate

2 – 26 l/min

Min. inlet pressure at
suction side at

50

0

C

82

0

C

95

0

C

110

0

C

5 – 26 l/min

2-26 l/min

0.05 bar

0.05 bar

0.05 bar

0.15 bar

0.15 bar

0.15 bar

0.3 bar

0.3 bar

0.3 bar

1.1 bar

1.4 bar

-

Maximum static pressure

10 bar (102m water gauge)

10 bar (102m water gauge)

10 bar (102m water gauge)

Maximum Ambient temperature

55

0

C

35

0

C

40

0

C

Recommended cable type

Power Consumption

HOFR 3 x 0.75mm

2

85

0

C

Rating Plate

HOFR 3 x 0.75mm

2

85

0

C

Rating Plate

HO5 VV-F 3 G1.5

Rating Plate

GB

8573 Nocchi Booklet 12 linguil 4124349:Pentair Water Italy Srl - Reb

Содержание R2SE

Страница 1: ...uik en 32 onderhound 38 Manual de utilizi o e manuten o 44 K itt ja kunnssapito 50 Bruks och underh lls anvisningar 56 Uputsvo za upotrebu i odrzavanje 62 Instruksjonsh ndbok og vedlikehold 68 I F GB...

Страница 2: ...sabilit que les produits de la s rie SR3 R2SE sont conformes aux Conditions Essentielles de S crurit et de Tutelle de la Sant selon les Directives 98 37 73 23 89 336 et leurs modifications suivantes P...

Страница 3: ...iceras i direktiven 98 37 73 23 89 336 och senare till gg SR3 R2SE PENTAIR PUMPS S p A intygar under sitt eget ansvar att elpumparna nedan SAMSVARSERKL RING Firmaet Pentair Water Italy Srl erkl rer un...

Страница 4: ...domestic central heating systems only 1 2 Product Data SR3 xx 40 SR3 xx 50 SR3 xx 60 SR3 25 70 R2SE ConnectionVoltage 1 230V 10 50Hz 1 230V 10 50Hz 1 230V 10 50Hz Insulation class H 1800 C H 180 C F 1...

Страница 5: ...for earthing the outer casing is provided Standard Pumps Models offer a single or variable speed setting to allow system requirements to be accurately met Electronic Pumps The pump control channel is...

Страница 6: ...ng a pump maintain the same direction of flow 4 3 Electrical Connections ATTENTION Electrical work to be carried out by a competent qualified and licensed electricians in strict conformity to ruling n...

Страница 7: ...ent air within a short while of switching on In cases where the pump venting is slow identified by pump noise the pump bearings may be quickly vented by using a the manual restart knob Switch off the...

Страница 8: ...guarantee efficient operation of the heating installation and optimum adaptation of the pump to the load on the hydraulic installation it is important to select the right control range The pump contro...

Страница 9: ...ressure within the permissible limits Pump may require 48 hours to attain normal quiet operation Locked Pump Should the pump fail to start switch to maximum setting If the pump still does not start th...

Отзывы: