background image

3

NOBOCOOL NC-49DP/C

INTRODUCTION

This portable air conditioner can alter the room temperature and humidity.  It has multiple functions of cooling dehumidifying 
(drying) and fan ventilation, and can be moved from room to room and transported from building to building easily.

The air conditioner can maintain set room indoor air temperatures between 18°C and 32°C. The set room temperature is 
displayed on the remote control and in the control panel on the unit. This does not mean that the air conditioner will  necessarily 
reduce the actual room temperature to the set room temperature.

HOW YOUR 

NOBOCOOL

PORTABLE

A

REFRIGER TED

 

AIR CONDITIONER WORKS

Hot air is blown outside through the exhaust hose, using the 
window kit supplied with the air conditioner.

Air from the room is drawn into the air conditioner, cooled by
refrigeration, and blown into the room through the front grill.

 

 

Hot air must be exhausted outside the room being cooled, 
or you will not cool the room.

VARIABLES INFLUENCING THE COOLING 
EFFECTIVENESS OF THIS AIR CONDITIONER

The ability of the air conditioner to cool the air in your room depends  
on a number of variables. The critical variables are:

1. Orientation of the room to the sun.

Rooms facing North and West are exposed to the midday and afternoon 
sun, and are the hottest in the house. Rooms facing the morning sun
(East), and away from the sun (South), are the coolest in the house.

2

3. Air Draughts

4. Multi Storey Buildings

. Insulation 

Insulated roofs and walls reduce the amount of heat entering the room.
Windows admit heat into the room. This heat can be reduced if the windows are
protected from the direct sun (eg by outside blinds, well lined inside curtains, pergolas, thick foliage etc).

Rooms protected from draughts are more easily cooled. Windows and doors must be kept closed.

In multi storey buildings, upper storey rooms are usually hotter and therefore harder to cool than
ground floor rooms.

 

SIZING GUIDE

 

In general, the higher the cooling capacity (BTU/kW) of an air conditioner, the bigger the room it
will cool.

This 17,000 BTU air conditioner, subject to the variables explained in box 2, can effectively cool
rooms with a floor area of between 16 and 36 square metres.

N

S

E

W

afternoon

sun

morning

sun

1

2

3

Example 1:

 

Uni nsulated upper storey

 room with one West facing

external wall. 

In this example, the air
conditioner is suitable for
effectively cooling a room
of up to 16 square metres.

Example 2:

 Insulated ground floor

 

room with external

 

walls facing East

 

and/or South. 

In this example, the air
conditioner is suitable for
effectively cooling a room
of up to 36 square metres.

4m

4m

Example of maximum 

room size 

4m x 4m = 16m

2

6m

6m

Example of maximum 

room size 

6m x 6m = 36m

2

MEGA

cool air

room air

hot  air

(outside)

Содержание NC-49DC

Страница 1: ...er manual carefully before using Any enquiries should be directed to NOBO on 1800 my nobo or 1800 69 6626 in the rst instance PORTABLE REFRIGERATED AIR CONDITIONER USER MANUAL For NC 49DP C NOBO 17 Br...

Страница 2: ...r o f e b t e l t u o r e w o p e h t m o r f t i n u e h t g u l p n u s y a w l A filter cleaning Do not place the air conditioner or plastic window slider in direct sunlight For maximum cooling ef...

Страница 3: ...duction 3 Installation 6 Control panel 10 Operation of control panel 10 Operation of remote control 12 Water drainage methods 14 Maintenance and service 15 Trouble shooting 17 2 NOBOCOOL NC 49DP C Spe...

Страница 4: ...un and are the hottest in the house Rooms facing the morning sun East and away from the sun South are the coolest in the house 2 3 Air Draughts 4 Multi Storey Buildings Insulation Insulated roofs and...

Страница 5: ...re In COOLING MODE once the existing room temperature reaches the set temperature the fan continues operating and the compressor switches on and off to maintain the set temperature within the room For...

Страница 6: ...djusted air fins 3 Air outlet 4 Left Right auto air swinging fins 5 Rolling castor 6 Cable power cord and plug BACK Fig 2 1 Hot air outlet grill 2 Low air inlet grill 3 High air inlet grill 4 Power co...

Страница 7: ...tlets cannot be covered up Place the unit no less than 50cm away from a wall or other obstacle INSTALLATION ACCESSORIES 6 5 0 c m 50cm Fig 3 user manual remote control batteries 50cm clearance at back...

Страница 8: ...care to not break the tabs on the window adaptor when disconnecting from the window slider MOUNTING OF ASSEMBLED AIR EXHAUST HOSE Fig 5 Take care not to damage the hose inlet when attaching detatchin...

Страница 9: ...king This will ensure maximum cooling output Never move the appliance by pulling the air exhaust hose attached to the back of the appliance Do not move the air conditioner when it is operating Correct...

Страница 10: ...e to install Please refer to illustration for minimum and maximum window openings Additional complete window kits may be purchased from NOBO to enable pre installation in windows in other rooms Insert...

Страница 11: ...perating R DRY MODE LIGHT illuminated when in DRY mode S COOLING MODE LIGHT illuminated when in COOLING mode OPERATION OF CONTROL PANEL The operating temperature ranges for cooling and dehumidifying a...

Страница 12: ...e does not need to be connected SETTING THE TIMER This timer can be used to delay the appliance start up or shutdown This avoids wasting electricity by optimizing operating periods PROGRAMMED SHUTDOWN...

Страница 13: ...remote control expose it to direct sunlight or leave it near sources of heat COOL DRY FAN HIGH MED LOW SWING TIMER ON TIMER OFF MODE FAN SWING ON OFF TIMER AUTO TIMER selection MODE selection FAN spe...

Страница 14: ...longer than ten hours one hour intervals can be selected Press the TIMER button again to confirm the timer setting the TIMER INDICATOR LIGHT lights up and keeps flashing to indicate the timer is acti...

Страница 15: ...upwards from the front until no more water drains from the outlet This air conditioner is equipped with the very latest MIST technology which means that the water tank does not have to be emptied This...

Страница 16: ...ty of the unit Clean the surface of the unit with a damp cloth then dry with a duster or similar CLEANING THE AIR FILTER Clean the dust filter once every two weeks of operation This will keep the air...

Страница 17: ...nto the drain pan and dispose of the water Tilt the unit by lifting it at the front to ensure all water is removed from the water tank Then operate the unit in fan mode for half a day until the pipe i...

Страница 18: ...ter turning on Is timer on Wait for timer to count down or cancel timer setting by pressing Is compressor light illuminated Wait 3 minutes from turning on safety device prevents compressor which provi...

Страница 19: ...isplayed contact Nobo on 1800 my nobo or 1800 69 6626 Ft FULL TANK The water tank is full Empty the internal tank see the section on Water Drainage Method This is a fail safe display due to protect ag...

Отзывы: