OPERATION
Speed Scrub
t
2701/3301 (06–01)
11
BATTERY CHARGING
The following charging instructions are intended
for supplied chargers only. If you don’t have a
supplied battery charger, use a charger with the
following specifications listed below. Improper
charger may cause battery damage.
CHARGER SPECIFICATIONS:
S
OUTPUT VOLTAGE – 24 VOLTS
S
OUTPUT CURRENT – 25 AMPS
S
AUTOMATIC SHUT–OFF CIRCUIT
S
FOR LEAD ACID DEEP CYCLE BATTERY CHARGING
NOTE: Recharge batteries ONLY after a total of 30
minutes or more of use. This will prolong battery life.
WARNING: Batteries emit hydrogen gas.
Explosion or fire can result. Keep sparks and
open flame away. Keep battery compartment open
when charging.
FOR SAFETY: When servicing machine, wear
protective gloves when handling batteries or
battery cables. Avoid contact with battery acid.
1.
Transport machine to a well ventilated area when
charging.
2.
Turn machine power off.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
3.
Hinge open recovery tank to access batteries.
Make sure recovery tank is empty before opening
(Figure 20).
FIG. 20
4.
Before charging batteries, check fluid level (A) in
each battery cell. If battery plates (B) are exposed,
add just enough distilled water to cover plates,
level (A). Never add acid to batteries. DO NOT
overfill. Batteries can overflow during charging due
to expansion. Do not charge batteries unless fluid
is slightly covering battery plates (B). Replace cell
caps before charging (Figure 21).
A
B
FIG. 21
5.
With charger’s power supply cord unpluged,
connect battery charger to machine. Flip up tank
support stand and rest tank on stand (Figure 22).
FIG. 22
6.
Plug battery charger cord into a grounded wall
outlet (Figure 23).
Grounded Outlet
Grounding
Edge/hole
Grounded
3 Hole Outlet
Ground Pin
(120V)
(230V)
FIG. 23