![Nobles Speed Scrub 1701 Plus Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/nobles/speed-scrub-1701-plus/speed-scrub-1701-plus_operator-and-parts-manual_1698152006.webp)
OPERATION
6
Speed Scrub
1701 Plus (12–00)
6.
Connect black battery cable coming from machine
to negative (–) post of top battery. Then connect
opposite end of black jumper cable to positive (+)
post (Figure 4).
(+)
(–)
(+)
(–)
Black
Cable
Red Cable
Jumper
Cable
Jumper
Cable
TOP
BATTERY
BOTTOM
BATTERY
FIG. 4
7.
Reconnect vacuum hose to recovery tank snout
as shown (Figure 5).
FIG. 5
8.
After batteries are properly installed, turn on key
and vacuum switch and check battery meter
charge level. Charge if necessary (See BATTERY
CHARGING) (Figure 6).
FIG. 6
MACHINE SETUP
ATTACHING SQUEEGEE ASSEMBLY
1.
Raise squeegee mount bracket by moving
squeegee lift knob to the left (Figure 7).
FIG. 7
2.
Loosen two thumb knobs on squeegee assembly
and slide squeegee into slots on squeegee mount
bracket (Figure 8).
FIG. 8
3.
Tighten thumb knobs securely.
4.
Connect vacuum hose from machine to squeegee
assembly (Figure 9).
FIG. 9