OPERATION
12
Speed Scrub
1701 Plus (12–00)
DRAINING TANKS
When to drain recovery tank:
– After each use.
– Between solution tank fill ups.
– When solution flow stops during operation.
– When ball float screen is activated.
– When squeegee starts trailing water.
NOTE: If using the ES
t
recycling system, be certain
to drain and rinse both tanks after each use.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
DRAINING RECOVERY TANK
ATTENTION: Drain recovery tank when refilling
solution tank. Foam or water may enter ball float
screen and damage vacuum motor. Vacuum
motor damage due to foam or water is not covered
by warranty.
1.
Push machine to floor drain and turn off all
switches. Remove left side drain hose from holder,
position hose over drain, twist loose, and remove
drain hose plug (Figure 31).
FIG. 31
NOTE: If using a bucket to drain machine, do not use
same bucket for filling, or be certain to rinse it out
before refilling machine.
2.
Open clear recovery tank lid and rinse tank, ball
float screen and ES
filter if equipped. Remove
and rinse ball float screen and ES
filter if they
are excessively dirty. Replace screen and filter
securely.
3.
Replace drain hose plug securely when empty.
DRAINING SOLUTION TANK
To drain unused cleaning solution or recycled solution
from solution tank, follow steps below:
1.
Remove clear drain hose from hose barb, position
hose over drain (Figure 32).
FIG. 32
2.
Rinse out solution tank and solution flow system
with clean water to prevent clogging due to
chemical buildup.
3.
Replace drain hose securely on hose barb when
empty.