OPERATION
Speed Scrub 2601 Cylindrical Brush (12--02)
21
RECOMMENDED STOCK ITEMS
Refer to Parts List section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No power.
Faulty main switch.
Contact Service Center.
Batteries need charging.
See CHARGING BATTERIES.
Faulty battery(s).
Replace battery(s).
Loose battery cable.
Tighten loose cable.
MAIN circuit breaker has tripped.
Determine cause and reset circuit
breaker button.
Optional power kill button activated.
Turn button clockwise to reset.
Brush motors do not operate.
Control grips are not rotated.
Rotate control grips.
Brush circuit breaker(s) has tripped.
Clean or replace brushes and reset
brush circuit breaker button.
Faulty brush motor or wiring.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Faulty brush roll switch or solenoid.
Contact Service Center.
Vacuum motor does not operate.
Faulty vacuum switch.
Contact Service Center.
Vacuum circuit breaker has tripped.
Remove obstruction and reset
breaker.
Faulty vacuum motor or wiring.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Drive motor does not operate.
Drive motor circuit breaker has
tripped.
Determine cause and reset breaker.
Faulty speed control circuit board or
connection.
Contact Service Center.
Faulty solenoid.
Contact Service Center.
Faulty drive motor.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Worn carbon brushes.
Contact Service Center.
Drive motor operates improperly.
Faulty potentiometer or speed control
board.
Contact Service Center.
Loose wire connection
Contact Service Center.