3
Residual Capacity at different lifting height
2 SAFETY GUIDANCE
2.1 Operator should read all warning signs and instructions here and on the stacker before using it.
2.2 Do not operate a stacker unless you are familiar with it and have been trained or authorized to do
so.
2.3 Do not operate a stacker unless you have checked its condition. Give special attention to the chain,
the wheels, the handle, the guide frame, the pilot wheel, the mast, battery, etc.
2.4 Do not use on a slopping ground or on a barbaric or explosive danger environment.
2.5 Do not take up any people on the forks.
2.6 When forks lifting, forbid anyone to stand under the forks or pass through the forks.
2.7 The operator had better take on gloves for labor protecting.
2.8 Do not move the stacker when the goods are lifted to the height more than 300mm.
2.9 When the goods have been transported or lifted, all people should be away from the forks for
600mm.
2.10 The weight of goods should be distributed on the two forks, do not use only one fork. The center
of gravity of goods should be in the center of two forks.
2.11 Do not load over maximum capacity.
2.12 Before using or charging it, check cell liquid, if not enough, full it with distilled water.
2.13 Charging should be in dry and ventilated location, and far away from the fire.
2.14 Keeping the forks in the lowest position if not using.
2.15 At other special condition or place, the operator should be carefully to operate the stacker.
3 MAINTENANCE
3.1 Hydraulic oil
Please check the oil level every six months. The oil can be hydraulic oil:
ISO VG32
, its viscosity
should be 32cSt at 40
o
C, total volume is about 4.0lt. use temperature -20
o
C~50
o
C
Replace the hydranlic oil (every 12 months).
3.2 Daily check and maintenance
It is necessary to check the stacker daily. Special attention should be paid to the wheels, the axles,
as thread, rags, etc., it may block the wheels, the fork and the mast, the chain, the battery should be
checked, too. The forks should be unloaded and lowered in the lowest position when the job is over.
Up to h3 mm
ACTUAL CAPACITY ( Q ) kg
1500
1500
2500
1500
3000
800
Load centre distance ( C )
mm
600