INSTRUCTIONS
INSTALLATION
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
The data plate is located on the right side of the machine. Refer to the data plate for
machine operating requirements, machine voltage, total amperage, and serial number.
1. Open electrical box at bottom-front of machine by using a phillips screwdriver to
remove the two screws.
2. Install 3/4” conduit into the pre-punched hole in bottom of electrical box.
3. Route power wires and connect to power block and grounding lug.
4. Install service wires (L3 for 3-Phase only) to the appropriate terminal.
5. Install the grounding wire into the lug provided.
6. Tighten the connections.
“DE-OX” or similar anti-oxidation agent should be used on all power
connections.
On 460 V 3-Phase machines only, correct pump motor rotation must be verified
before the machine is operated. Failure to do so can result in damage to the
machine and components.
1. Follow the "Filling the Wash Tub" section.
2. Locate the wash pump motor and identify the arrow decal which shows the
correct motor rotation (if no decal is present, correct rotation is away from the
pump volute).
3. Start the machine.
4. Observe the rotation of motor fan and quickly stop the machine.
5. If rotation is incorrect, disconnect electrical power and reverse the L1 and L2
connections at terminal block shown in the section above.
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power supplies and
lockout/tagout in
accordance with
appropriate procedures
and codes at the
disconnect switch.
MOTOR ROTATION
i
Imbalanced
wild leg goes
to L3.
NOTICE
NOTICE
CAUTION!
On 460 V
3-Phase machines only,
correct pump motor
rotation must be verified
before operation!
!
CAUTION
If necessary, see
"Heaters" page for
phase conversion kit.
Pump Volute
Motor Fan
3
Φ
Содержание HT-180EC
Страница 27: ...07610 004 92 22 A 22 ELECTRICAL BOX PARTS 20 10 9 19 7 6 11 12 18 7 13 14 13 7 8 15 16 4 2 3 6 17 1 8 7...
Страница 29: ...07610 004 92 22 A 24 HOOD PARTS 1 2 3 4 4 5 6 1 5 7 7...
Страница 33: ...07610 004 92 22 A 28 TUB PARTS 1 3 2 9 7 6 4 8 5 11 10 12 13 14 15 16 19 18 17 21 22 23 20...
Страница 47: ...07610 004 92 22 A 42 SCHEMATICS 208 230 460 V 50 60 HZ 1 PH 3 PH HT 180EC...