INSTRUCTIONS
INSTALLATION
PRESSURE
REGULATOR
SHOCK ABSORBER
CONNECTING THE
DRAIN LINE
The manufacturer recommends the installation of a pressure regulating valve (PRV)
in the incoming water line to ensure proper flowrate at all times and offers these
devices as options (see the Plumbing Options page).
Do not confuse static pressure with flow pressure. Static pressure is the line pressure
in a “no flow” condition (all valves and services are closed). Flow pressure is the
pressure in the fill line when the fill valve is opened during the cycle.
The manufacturer also recommends the installation of a shock absorber in the
incoming water line and offers these devices as options (see the Plumbing Options
page). This prevents line hammer/hydraulic shock—induced by the solenoid valve as
it operates—from causing damage to the equipment.
The machine's drain is a gravity-discharge drain. All piping from the 1 1/2” NPT
connection on the wash tank must be pitched (1/4” per foot) to the floor or sink drain.
All piping from the machine to the drain must be a minimum 1 1/2” NPT and must not
be reduced. There must also be an air-gap between the machine drain line and the
floor sink or drain. If a grease trap is required by code, it should have a flow capacity
of 5 GPM.
Remove control box lid and make chemical and exhaust fan connections at the
points shown below:
CHEMICAL &
EXHAUST FAN
ELECTRICAL
CONNECTIONS
EXHAUST FAN
CONTROL
CONNECTION
EXHAUST FAN
CONTROL
CONNECTION
RINSE AID
DISPENSER
CONNECTION
DETERGENT
DISPENSER
CONNECTION
CONSTANT
VOLTAGE
CONNECTION
L1 TO EXHAUST
FAN CONTACTOR
COIL
3 AMP SLOW BLOW
FUSE
CUSTOMER
EXTERNAL VOLTAGE
SOURCE FOR FAN
CONTACTOR COIL,
240V MAX
3 AMP SLOW BLOW
FUSE
L1 208-240V
OUTPUT
LIVE WHEN RINSE
VALVE IS OPEN
3 AMP SLOW BLOW
FUSE
L1 208-240V
OUTPUT
LIVE WHEN WASH
PUMP IS ON
3 AMP SLOW BLOW
FUSE
L1 208-240V
OUTPUT
LIVE WHEN MACHINE
POWER IS ON
3 AMP SLOW BLOW
FUSE
F2
F3
F4
F5
F6
L2 (TO CHEMICAL
DISPENSERS)
Содержание HT-180EC
Страница 27: ...07610 004 92 22 A 22 ELECTRICAL BOX PARTS 20 10 9 19 7 6 11 12 18 7 13 14 13 7 8 15 16 4 2 3 6 17 1 8 7...
Страница 29: ...07610 004 92 22 A 24 HOOD PARTS 1 2 3 4 4 5 6 1 5 7 7...
Страница 33: ...07610 004 92 22 A 28 TUB PARTS 1 3 2 9 7 6 4 8 5 11 10 12 13 14 15 16 19 18 17 21 22 23 20...
Страница 47: ...07610 004 92 22 A 42 SCHEMATICS 208 230 460 V 50 60 HZ 1 PH 3 PH HT 180EC...