 - r. 0

6. 

Starting-up and adjustments

At the starting-up of the system, when the system is re-started after a long non-working

period, and after a cleaning operation, the membranes are filled with preservative or detergent
chemical.

Hence, in any cases, it is required to remove completely the preservative or detergent from

the membranes before that treated water can be used.

The operations are made as follows : (see "

DIAGRAM OF THE SYSTEM"

)

  

  be sure that the power switch of power control panel 

QE

 is OFF (main switch on “0”)

  connect temporarily the auxiliary fitting R to the drain

  divert, temporarily also the permeate line to the

drain, by turning the 3-way valve V3 on cleaning
position,  (the direction of the flow towards the fitting
R, check the direction with the symbol marked on the
lever of 3-ways valves).

  close completely the needle regulation valve 

VR

  open completely the needle regulation valve 

VS

  open slowly the water inlet valve of the system. In order to make easy the filling of the

filter 

F

, open slowly the valve placed on the top side of the filter

  switch ON the main power of 

QE 

control board

  (

turning

 

on

 

"1" position), and switch the

mode selector of the pump on "MAN" position; the RO unit will start to work.

  after several minutes of working (

check carefully that there is required minimum

pressure of water inlet, by the pressure gauges M1 and M2: the minimum pressure
control is out of working when the mode selector is on “MAN” position

), the service

flow rates can be checked and adjusted.

  adjust the needle valve 

VS, 

mounted along the the drain line of the membranes, in order

that the flow rate of permeate (flow meter 

F1) 

meets the technical data of the system. The

value of pressure shown on pressure gauge 

M4,

 after the adjustment of 

VS

 valve, is the

normal working pressure of the system according to the available raw water quality
(chemical composition, temperature, etc.)

An adjustable recirculating system is available in order to reduce the quantity of

concentrated

 (drain) water and/or reduce the working pressure; proceed as follows :

  adjust the needle valve 

VR

 to recirculate part of concentrated water in order to reduce the

flow rate of water actually carried to drain. The adjustment of the valve 

VR

 causes also

the modification of the working pressure, hence a new adjustment of valve 

VS

 is required,

until both values pressure/flow rate are the ones desired.

  The valve VRP, mounted downstream of the pump P, allows to throttle the forcing line of

the pump, in order to allow to reduce both the pressure and the flow rate on membranes.
This feature can be useful for the system to run at low pressure, without recirculationg or
draining a too high flow of water.
A “too high flow” means the one that causes a pressure drop, across the membranes,
over than 3 bars (300 kPa) for each housing (difference of pressure between M3-M5 and
M5-M4).
This needing happens more often with new membranes, when they produce the max flow.

Содержание RO 809 /E

Страница 1: ...ration Proceed strictly according to all directions included in this manual Reverse osmosis systems models RO E are designed to treat raw water supplied from municipalities or from well ANY OTHER APPL...

Страница 2: ...mmands and visualizations 10 5 2 Logical programmer 11 5 2 1 Reports on the display of the programmer 13 5 2 2 How to set current time and day 13 5 2 3 How to set times and delays 13 5 2 4 How to use...

Страница 3: ...ons flushing solenoid valve diagram PLACING special instructions pilot solenoid valves diagram MEMBRANES WASHING special instructions automatic ball valves diagram FRONT OF CONTROL PANEL special instr...

Страница 4: ...d personal protection devices if required CE marked according to safety regulations for working areas The operators must be aware of the hazards and danger of the chemicals used in the process In case...

Страница 5: ...al osmotic flow is reversed Reversal is effected by the application of pressure greater than the osmotic pressure to the concentrated solution Fresh water diffuses through the membrane practically con...

Страница 6: ...RO812 E RO815 E TDS of treated water 3 of raw water power supply V ph Hz 400 3 50 power kW 15 18 5 22 working pressure bar kPa approx 16 1600 max allowable pressure bar kPa 22 2200 permeate t 15 C l...

Страница 7: ...des Keep the cards and everything contained inside the packaging 4 3 How to move and lift the unit Some of the pipes of the plant are made in plastic material hence they can be easily damaged Do not l...

Страница 8: ...and concentrate during these operation FOR SYSTEMS ARRANGED FOR FLUSHING WITH RO PROCESSED WATER ONLY Connect the intake of RO processed water for flushing to the inlet fitting IF using pipes made in...

Страница 9: ...o 12 o max level LH open without water o o pilot solenoid valve EI of the inlet valve VI o 17 o o o GND o o flushing solenoid valve EF pilot solenoid valve EIF if installed o 18 o o o GND o 20 o free...

Страница 10: ...uts and outputs and allows to modify the pre set time of the used timers see special chapter for details The commands available on the front of control panel QE are EMERGENCY STOP It is placed on the...

Страница 11: ...feed back from pump P contactor that the pump is ON when this pump should be ON automatic command This alarm switches the block of the whole system the alarm and its block can be reset by turning the...

Страница 12: ...vated alarm I8 Input of the pump working signal Q1 output for the inlet pilot solenoid valve EI Q2 output for the pump P Q3 output for the flushing solenoid valve EF Q4 output for the alarms joined si...

Страница 13: ...tions 8 push the button ESC to go back to the visualization of service 5 2 3 How to set times and delays Proceed as follows to make any modification 1 push the button ESC 2 push the button until the p...

Страница 14: ...eed as follows to use the function buttons see also the chapter How to use the function buttons of the programmer push several times the button until the notice ESC C is visualized on the display push...

Страница 15: ...g The times of the flushing features during and at the end of working are both adjustable separately by the programmer as described above The solenoid valve EF can be also hand driven opened at any mo...

Страница 16: ...LUSHING 5 3 9 2 Automatic flushing during stand by This option is available only together with the option Flushing with RO treated water The selector FLUSH ST BY is available on the front of the contr...

Страница 17: ...water is intaken from storage tank at atmospheric pressure and not from pressurized mains the pressure switch PC is not suitable to control the water pressure during flushing Therefore the function of...

Страница 18: ...e of water inlet by the pressure gauges M1 and M2 the minimum pressure control is out of working when the mode selector is on MAN position the service flow rates can be checked and adjusted adjust the...

Страница 19: ...d water drain water permeate concentrated can be decided according to the characteristics of raw water The higher is the value of the ratio the higher is the risk of membrane fouling furthermore if th...

Страница 20: ...tch OFF the main power and close the inlet shut off ball valve V1 for refills see the attached special instructions of the filters replace the RO membranes when the quality and or quantity of treated...

Страница 21: ...e housings pushing them according to the arrows marked on the housings rinse each and every new membrane with plenty running water to remove most of the preservative solution of which the membrane is...

Страница 22: ...p P on the control panel QE on 0 position close the shut off valve V1 upstream of the filters turn the 3 ways valves V2 and V3 on cleaning position the direction of the flow towards the fitting R chec...

Страница 23: ...adjust the turns of the internal screw of the pressure switch until the correct set point is reached to check if the adjustment has been correctly made put on again for a while the cap on the electri...

Страница 24: ...DTA sodio etilen diammino tetra acetato Na DDS sodio dodecilsulfato STP sodio trifosfato Na5P3O10 TSP fosfato trisodico Na3PO4 12H2O HCl acido cloridrico H3PO4 acido fosforico NH2SO3H acido sulfammico...

Страница 25: ...rfectly There is air inside the pump The pump is spoiled Adjust correctly valve VS and or VR and or VRP Clean or replace the solenoid valve Purge air off the pump Repair and or replace the pump Minimu...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Отзывы: