Nobel aelios Скачать руководство пользователя страница 27

STEP 17

STEP 14

STEP 12

STEP 19

STEP 16

*

12. 

Place and tighten the Ø22 mechanically tightened plug on the top right and on the bottom left of the collector/ 

collectors*.  Place the water storage tank on the base with its electrical components to the left, when viewing the 

water storage tank from the front. 

13. 

Center the water storage tank’s position on the collector/s. Rotate the water storage tank (if necessary) in order 

for the cold and hot domestic water sockets to remain vertical to the horizontal surface. Screw the water storage 

tank onto the base using the screws provided in the packaging. Ensure the appliance is not tilted and is properly 

levelled. It is necessary to use a level.

14. 

Place the small flexible tube on the special connection 3/4”xDN16 INOX* at the water storage tank’s side where 

the heating element is located and to the socket marked “collector intake”. 

15. 

Join the other end to the top left socket of the collector using the Ø22xDN16 INOX corner fitting*, having firstly 

passed the tube through the insulation pipe.

16. 

Place the Τ-piece with the filling valve to the socket on the right side of the water storage tank marked “collector 

return”. Place the big flexible tube with the special connection to the T-piece on the right side of the water storage 

tank.

17. 

Place the other end at the bottom right socket of the collector using the Ø22xDN16 INOX corner fitting*, having 

firstly passed the tube through the insulation tube. Tighten all unions in the system as well as all the screws on 

the base. Do the hydraulic connection, fill the closed loop and do the electrical connection as described in the 

relevant sections. Check for leaks.

18. 

After having placed the collectors at a parallel to each other position, fasten them to the support base tightening 

the fixing washers 

8

19. 

Fit the water storage tank supporting base covers 

9

.

Use two wrench keys in order to avoid the copper tube mechanical strain.

Solar water heaters

27

26

Solar water heaters - AELIOS

Solar water heaters - AELIOS

Содержание aelios

Страница 1: ...Solar water heaters Technical Manual Installation maintenance use instructions...

Страница 2: ...2 Solar water heaters AELIOS...

Страница 3: ...m2 LAYOUT 18 AELIOS 300lt 4m2 LAYOUT 19 AELIOS 300lt 6m2 LAYOUT 20 GENERAL INSTALLATION RULES 21 INSTALLATION POSITION 22 GENERAL PREVENTION MEASURES 23 SUPPORT BASE PARTS 24 SUPPORT BASE ASSEMBLY ON...

Страница 4: ...duce hot water during the daylight hours maintaining thus its maximum efficiency SOLAR WATER HEATER OPERATION WATER HEATING The collecting surface absorbs solar energy and heats the liquid water or a...

Страница 5: ...with low sunlight they achieve the preheating of the water which contributes to a drastically reduced consumption of conventional energy With the use of solar systems thermosiphonic or forced circulat...

Страница 6: ...DN16 1 PC SAFETY VALVE 1 5 bar for 250lt and above or 2 5 bar up to 200lt 1 PC SAFETY VALVE 1 5 bar for 250lt and above or 2 5 bar up to 200lt 1 PC INSULATION 22 X 9 2 PCS INOX TUBE DN16 2 PCS INOX TU...

Страница 7: ...ure Permissible operating pressure of the collector heat transfer medium XXX KPa Electrical Power XXX W Storage Tank S N Date of manufacture Solar water heater AELIOS xxxlt xm2 Type Flatplate collecto...

Страница 8: ...rotecting it against electrolysis and corrosion specially made to withstand the generally accepted specifications with regard to the heat resistance 8 Heating element rated according to the country of...

Страница 9: ...rption 4 Complete area absorber made of black painted aluminium 0 3mm thick or selective aluminium 0 4mm thick covers the complete window area as well as the headers thus increasing the collector s ab...

Страница 10: ...e increases heat loss Complete area technology The uniform area prevents heat loss FLAT SURFACE INCLINED SURFACE Supporting base system made of galvanised steel for installation on flat or inclined su...

Страница 11: ...5 2 90 2 84 2 NO Part Name DIM mm QTY 1 Beam L Laminate section 60 x 2 5mm 2060 x 60 2 2 Beam L Laminate section 60 x 2 5mm 1224 x 60 2 3 Beam L Laminate section 60 x 2 5mm 2289 x 60 2 4 Beam L Lamin...

Страница 12: ...1 Beam L Laminate section 60 x 2 5mm 2060 x 60 2 2 Beam L Laminate section 60 x 2 5mm 2289 x 60 2 3 Beam L Laminate section 60 x 2 5mm 925 x 60 2 4 Beam L Laminate section 33 x 2mm 980 2 5 Beam Lamin...

Страница 13: ...Laminate section 60 x 2 5mm 2060 x 60 2 2 Beam L Laminate section 60 x 2 5mm 2289 x 60 2 3 Beam L Laminate section 60 x 2 5mm 925 x 60 2 4 Beam L Laminate section 33 x 2mm 980 2 5 Beam Laminate sectio...

Страница 14: ...er 8 12 WATER STORAGE TANK 160lt DIMENSIONS mm 580x1116 WEIGHT EMPTY kg without packaging 66 8 JACKET CAPACITY lt 9 JACKET SURFACE m2 0 91 MAX TEST PRESSURE bar 15 MAX OPERATING PRESSURE bar 10 TOTAL...

Страница 15: ...ORAGE TANK 200lt DIMENSIONS mm 580x1356 WEIGHT EMPTY kg without packaging 81 8 JACKET CAPACITY lt 13 JACKET SURFACE m2 1 28 MAX TEST PRESSURE bar 15 MAX OPERATING PRESSURE bar 10 TOTAL SYSTEM AELIOS 2...

Страница 16: ...Y 1 Beam L Laminate section 60 x 2 5mm 2060 x 60 2 2 Beam L Laminate section 60 x 2 5mm 1224 x 60 2 3 Beam L Laminate section 60 x 2 5mm 2289 x 60 2 4 Beam L Laminate section 60 x 2 5mm 925 x 60 2 5 B...

Страница 17: ...2 WATER STORAGE TANK 200lt DIMENSIONS mm 580x1356 WEIGHT EMPTY kg without packaging 81 8 JACKET CAPACITY lt 13 JACKET SURFACE m2 1 28 MAX TEST PRESSURE bar 15 MAX OPERATING PRESSURE bar 10 TOTAL SYSTE...

Страница 18: ...8 12 WATER STORAGE TANK 200lt DIMENSIONS mm 580x1356 WEIGHT EMPTY kg without packaging 81 8 JACKET CAPACITY lt 13 JACKET SURFACE m2 1 28 MAX TEST PRESSURE bar 15 MAX OPERATING PRESSURE bar 10 TOTAL SY...

Страница 19: ...r 8 12 WATER STORAGE TANK 300lt DIMENSIONS mm 580x1970 WEIGHT EMPTY kg without packaging 114 5 JACKET CAPACITY lt 19 JACKET SURFACE m2 1 79 MAX TEST PRESSURE bar 15 MAX OPERATING PRESSURE bar 10 TOTAL...

Страница 20: ...TANK 300lt DIMENSIONS mm 580x1970 WEIGHT EMPTY kg without packaging 114 5 JACKET CAPACITY lt 19 JACKET SURFACE m2 1 79 MAX TEST PRESSURE bar 15 MAX OPERATING PRESSURE bar 10 TOTAL SYSTEM AELIOS 300lt...

Страница 21: ...specific conditions that apply As the sun ray s angle of attack varies with time but also depend ing on the system s location the collector s angle should be approximately equal to the installation lo...

Страница 22: ...e clean tidy The warranty should be filled in and the customer should sign it and immediately mail it to the company The customer should fill in the check list provided by the company The company does...

Страница 23: ...by trained specialized electro technicians only Labour uniforms Have protection glasses on as well as appropriate work uniform protection shoes protection helmet and special long hair net Do not wear...

Страница 24: ...4 5 6 0 10 32 350 6 142 7 790 4 582 5 901 923 933 3 0 13 107 5 147 5 223 5 1547 1560 1 2 0 10 715 725 4 60 11 10 0 2047 2060 0 11 2 60 60 0 114 990 2277 66 60 0 792 1190 1224 92 0 490 60 0 10 110 SUPP...

Страница 25: ...ixing washers 8 without tightening the M8 screws with the nuts In case of one collector model you don t need to use part 5 The collector is going to be fixed with the 2 collectors fixing washers 8 as...

Страница 26: ...r and above screw reinforcing plate 10 to collector beam 2 and vertical beam 3 with bolts M8x16 and nuts Repeat for another side 7 In case of installation of a three collectors system we place the 2 e...

Страница 27: ...he other end to the top left socket of the collector using the 22xDN16 INOX corner fitting having firstly passed the tube through the insulation pipe 16 Place the piece with the filling valve to the s...

Страница 28: ...ace part 4 between the two shape parts constructed in the former step 1 in order for the frame to be formed Screw straight parts 6 which will be used for the mounting of the support base to the tiles...

Страница 29: ...bases of a 1 collector system installing them in the same way on the left and the right side of the existing support base On the three support bases we place the three collectos according to the follo...

Страница 30: ...13 Join the other end to the top left socket of the collector using the 22xDN16 INOX corner fitting having firstly passed the tube through the insulation pipe 14 Place the piece with the filling valve...

Страница 31: ...specially designed filling fitting on the right of the water storage tank Image A2 fill approx half of the closed loop Add water to the anti freeze liquid putting double quantity of water in an empty...

Страница 32: ...nection switch with a mini mum distance between contacts of at least 3mm The circuit breaker s rating must be suitable for the heating element in use Caution A safety relay against electrical shock is...

Страница 33: ...ed The maximum distance between the collector outlet and the water storage tank inlet must not exceed 3m The angle of the pipe joining these 2 points must not be less than 8 SYSTEM INSTALLATION ON A T...

Страница 34: ...itions into consideration 2 Avoid large hot water consumption during the night 3 Check if your needs in hot water have increased and cannot be covered by the system s capacity 4 Make sure your solar w...

Страница 35: ...res 5 Remove the electrical heating element by removing the M8 screws 6 Remove the old magnesium bar from the heating el ement s flange 7 Screw in the new magnesium 8 Replace the heating element with...

Страница 36: ...of the pipe insulation and cleaning of the glass If the collector s glass is broken it should be replaced immediately It is recommended that the glass is washed at an hour of low sunlight to avoid dam...

Страница 37: ...done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the closed circuit the connections or in the tube heat exchanger Are the safety valves installed properly Does a m...

Страница 38: ...NOTES 38 Solar water heaters AELIOS...

Страница 39: ...Solar water heaters 39 Solar water heaters AELIOS...

Страница 40: ...RY 48 Vitosha Blvd Elin Pelin 2100 Sofia Region Bulgaria Tel 359 2 4210232 email info nobel bg The company preserves the right to change all specifications of the products and their accessories withou...

Отзывы: